Effective Dose Assessment for Patients Undergoing Contemporary Fluoroscopically Guided Interventional Procedures.

Publication ,  Journal Article
Li, X; Hirsch, JA; Rehani, MM; Yang, K; Liu, B
Published in: AJR Am J Roentgenol
January 2020

OBJECTIVE. The purpose of this study was to establish procedure-specific air kerma-area product (KAP) and effective dose for a large number of fluoroscopically guided interventional (FGI) procedures. MATERIALS AND METHODS. This retrospective study collected dose data for consecutive adult cases from 12 examination rooms between May 2016 and October 2018. A total of 24,911 cases (50.9% men) were categorized by procedure. Effective dose was calculated using KAP and procedure-specific KAP to effective dose conversion coefficients, mostly from National Council on Radiation Protection and Measurements (NCRP) Report 160. Data analysis was conducted with statistical software to determine mean value and five percentiles (10th, 25th, 50th, 75th, 95th). RESULTS. KAP and effective dose were presented for 101 procedures; a national benchmark is not available from NCRP Reports 168 and 172 for the KAP value of 89 procedures and for the effective dose of all 101 procedures. Twelve procedures that comprised at least 50% of patient cases had median KAP values less than 3.26 Gy · cm2 and a median effective dose of less than 0.70 mSv. However, some infrequent procedures might be associated with a higher dose. The 95th percentile of KAP was greater than or equal to 500 Gy · cm2 for 16 procedures and 985 Gy · cm2 for portography; for effective dose it was greater than or equal to 100 mSv for 21 procedures and 256 mSv for portography. CONCLUSION. The values for KAP and effective dose provided in this article can aid in design and review of clinical research protocols and dose management programs and in assessing compliance with the Joint Commission's standards for organizations providing fluoroscopy services in the absence of national benchmarks for more than 89 procedures.

Duke Scholars

Published In

AJR Am J Roentgenol

DOI

EISSN

1546-3141

Publication Date

January 2020

Volume

214

Issue

1

Start / End Page

158 / 170

Location

United States

Related Subject Headings

  • Young Adult
  • Retrospective Studies
  • Radiography, Interventional
  • Radiation Dosage
  • Nuclear Medicine & Medical Imaging
  • Middle Aged
  • Male
  • Humans
  • Fluoroscopy
  • Female
 

Citation

APA
Chicago
ICMJE
MLA
NLM
Li, X., Hirsch, J. A., Rehani, M. M., Yang, K., & Liu, B. (2020). Effective Dose Assessment for Patients Undergoing Contemporary Fluoroscopically Guided Interventional Procedures. AJR Am J Roentgenol, 214(1), 158–170. https://doi.org/10.2214/AJR.19.21804
Li, Xinhua, Joshua A. Hirsch, Madan M. Rehani, Kai Yang, and Bob Liu. “Effective Dose Assessment for Patients Undergoing Contemporary Fluoroscopically Guided Interventional Procedures.AJR Am J Roentgenol 214, no. 1 (January 2020): 158–70. https://doi.org/10.2214/AJR.19.21804.
Li X, Hirsch JA, Rehani MM, Yang K, Liu B. Effective Dose Assessment for Patients Undergoing Contemporary Fluoroscopically Guided Interventional Procedures. AJR Am J Roentgenol. 2020 Jan;214(1):158–70.
Li, Xinhua, et al. “Effective Dose Assessment for Patients Undergoing Contemporary Fluoroscopically Guided Interventional Procedures.AJR Am J Roentgenol, vol. 214, no. 1, Jan. 2020, pp. 158–70. Pubmed, doi:10.2214/AJR.19.21804.
Li X, Hirsch JA, Rehani MM, Yang K, Liu B. Effective Dose Assessment for Patients Undergoing Contemporary Fluoroscopically Guided Interventional Procedures. AJR Am J Roentgenol. 2020 Jan;214(1):158–170.

Published In

AJR Am J Roentgenol

DOI

EISSN

1546-3141

Publication Date

January 2020

Volume

214

Issue

1

Start / End Page

158 / 170

Location

United States

Related Subject Headings

  • Young Adult
  • Retrospective Studies
  • Radiography, Interventional
  • Radiation Dosage
  • Nuclear Medicine & Medical Imaging
  • Middle Aged
  • Male
  • Humans
  • Fluoroscopy
  • Female