Correction of beam hardening in X-ray radiograms.

Publication ,  Journal Article
Baur, M; Uhlmann, N; Pöschel, T; Schröter, M
Published in: The Review of scientific instruments
February 2019

The intensity of a monochromatic X-ray beam decreases exponentially with the distance it has traveled inside a material; this behavior is commonly referred to as Beer-Lambert's law. Knowledge of the material-specific attenuation coefficient μ allows us to determine the thickness of a sample from the intensity decrease the beam has experienced. However, classical X-ray tubes emit a polychromatic bremsstrahlung-spectrum. And the attenuation coefficients of all materials depend on the photon energy: photons with high energy are attenuated less than photons with low energy. In consequence, the X-ray spectrum changes while traveling through the medium; due to the relative increase in high energy photons, this effect is called beam hardening. For this varying spectrum, the Beer-Lambert law only remains valid if μ is replaced by an effective attenuation coefficient μeff which depends not only on the material but also on its thickness x and the details of the X-ray setup used. We present here a way to deduce μeff(x) from a small number of auxiliary measurements using a phenomenological model. This model can then be used to determine an unknown material thickness or in the case of a granular media its volume fraction.

Duke Scholars

Altmetric Attention Stats
Dimensions Citation Stats

Published In

The Review of scientific instruments

DOI

EISSN

1089-7623

ISSN

0034-6748

Publication Date

February 2019

Volume

90

Issue

2

Start / End Page

025108

Related Subject Headings

  • Applied Physics
  • 51 Physical sciences
  • 40 Engineering
  • 34 Chemical sciences
  • 09 Engineering
  • 03 Chemical Sciences
  • 02 Physical Sciences
 

Citation

APA
Chicago
ICMJE
MLA
NLM
Baur, M., Uhlmann, N., Pöschel, T., & Schröter, M. (2019). Correction of beam hardening in X-ray radiograms. The Review of Scientific Instruments, 90(2), 025108. https://doi.org/10.1063/1.5080540
Baur, Manuel, Norman Uhlmann, Thorsten Pöschel, and Matthias Schröter. “Correction of beam hardening in X-ray radiograms.The Review of Scientific Instruments 90, no. 2 (February 2019): 025108. https://doi.org/10.1063/1.5080540.
Baur M, Uhlmann N, Pöschel T, Schröter M. Correction of beam hardening in X-ray radiograms. The Review of scientific instruments. 2019 Feb;90(2):025108.
Baur, Manuel, et al. “Correction of beam hardening in X-ray radiograms.The Review of Scientific Instruments, vol. 90, no. 2, Feb. 2019, p. 025108. Epmc, doi:10.1063/1.5080540.
Baur M, Uhlmann N, Pöschel T, Schröter M. Correction of beam hardening in X-ray radiograms. The Review of scientific instruments. 2019 Feb;90(2):025108.

Published In

The Review of scientific instruments

DOI

EISSN

1089-7623

ISSN

0034-6748

Publication Date

February 2019

Volume

90

Issue

2

Start / End Page

025108

Related Subject Headings

  • Applied Physics
  • 51 Physical sciences
  • 40 Engineering
  • 34 Chemical sciences
  • 09 Engineering
  • 03 Chemical Sciences
  • 02 Physical Sciences