OBJECTIVE. The purpose of this article was to investigate the medical condition of patients who received substantial cumulative effective dose (CED) in fluoroscopically guided interventional (FGI) procedures. MATERIALS AND METHODS. We examined 25,253 patients (mean age, 58.2 years; 50.6% male) who underwent 46,491 FGI procedures at a tertiary care center in the United States from January 2010 to January 2019. Radiation dosage data were retrieved from an in-house semiautomated dose-tracking system. A cohort was identified as those who received a CED of 100 mSv or greater and was categorized by medical disorder from longitudinal medical records. Statistical software was used to determine mean value, five percentiles (10th, 25th, 50th, 75th, 95th), and interquartile range for age and dose. RESULTS. Among 1011 (4.0%) patients (30.4% female) with a CED of 100 mSv or more, the median number of procedures was 2.0, the median age at first procedure was 60.0 years old, and the median value of CED was 177.2 mSv. The patients' medical disorders included cancer (36.7%), chronic disease of the torso (30.0%), internal bleeding (24.8%), trauma (4.6%), organ transplant (3.2%) and cerebrovascular disease (0.7%). Eight-hundred (79.1%) patients underwent all of their procedures within 365 days. CONCLUSION. This is the first cohort study of the medical condition of patients receiving substantial cumulative doses from FGI procedures over a long period. In the critical care of patients with serious medical disorders, 4.0% of patients may be exposed to substantial radiation dose (CED ≥ 100 mSv). The risks associated with such a high level of radiation warrant continued attention.

Duke Scholars

Published In

AJR Am J Roentgenol

DOI

EISSN

1546-3141

Publication Date

August 2020

Volume

215

Issue

2

Start / End Page

433 / 440

Location

United States

Related Subject Headings

  • Surgery, Computer-Assisted
  • Radiation Dosage
  • Nuclear Medicine & Medical Imaging
  • Middle Aged
  • Male
  • Humans
  • Fluoroscopy
  • Female
  • Cohort Studies
  • Aged
 

Citation

APA
Chicago
ICMJE
MLA
NLM
Li, X., Hirsch, J. A., Rehani, M. M., Ganguli, S., Yang, K., & Liu, B. (2020). Radiation Effective Dose Above 100 mSv From Fluoroscopically Guided Intervention: Frequency and Patient Medical Condition. AJR Am J Roentgenol, 215(2), 433–440. https://doi.org/10.2214/AJR.19.22227
Li, Xinhua, Joshua A. Hirsch, Madan M. Rehani, Suvranu Ganguli, Kai Yang, and Bob Liu. “Radiation Effective Dose Above 100 mSv From Fluoroscopically Guided Intervention: Frequency and Patient Medical Condition.AJR Am J Roentgenol 215, no. 2 (August 2020): 433–40. https://doi.org/10.2214/AJR.19.22227.
Li X, Hirsch JA, Rehani MM, Ganguli S, Yang K, Liu B. Radiation Effective Dose Above 100 mSv From Fluoroscopically Guided Intervention: Frequency and Patient Medical Condition. AJR Am J Roentgenol. 2020 Aug;215(2):433–40.
Li, Xinhua, et al. “Radiation Effective Dose Above 100 mSv From Fluoroscopically Guided Intervention: Frequency and Patient Medical Condition.AJR Am J Roentgenol, vol. 215, no. 2, Aug. 2020, pp. 433–40. Pubmed, doi:10.2214/AJR.19.22227.
Li X, Hirsch JA, Rehani MM, Ganguli S, Yang K, Liu B. Radiation Effective Dose Above 100 mSv From Fluoroscopically Guided Intervention: Frequency and Patient Medical Condition. AJR Am J Roentgenol. 2020 Aug;215(2):433–440.

Published In

AJR Am J Roentgenol

DOI

EISSN

1546-3141

Publication Date

August 2020

Volume

215

Issue

2

Start / End Page

433 / 440

Location

United States

Related Subject Headings

  • Surgery, Computer-Assisted
  • Radiation Dosage
  • Nuclear Medicine & Medical Imaging
  • Middle Aged
  • Male
  • Humans
  • Fluoroscopy
  • Female
  • Cohort Studies
  • Aged