Skip to main content
release_alert
Welcome to the new Scholars 3.0! Read about new features and let us know what you think.
cancel
Journal cover image

Quantitation of 5-fluorouracil (5-FU) in human plasma by liquid chromatography/electrospray ionization tandem mass spectrometry.

Publication ,  Journal Article
Kosovec, JE; Egorin, MJ; Gjurich, S; Beumer, JH
Published in: Rapid Communications in Mass Spectrometry : Rcm
January 2008

5-Fluorouracil (5-FU) has long had a place in the treatment of many malignancies. 5-FU plasma concentrations have been correlated with toxicity and efficacy, and therapeutic drug monitoring has been reported to result in an improved response/toxicity balance. We report validation, according to FDA guidelines, of a hydrophilic interaction chromatography (HILIC) liquid chromatography/tandem mass spectrometry (LC/MS/MS) assay for the sensitive, accurate and precise quantitation of 5-FU in human plasma. The assay employed an isotopically labeled 5-FU internal standard and ethyl acetate extraction. Separation was achieved with an amino column and an isocratic mobile phase of 0.1% formic acid in acetonitrile/water (97:3, v/v), followed by a wash. Detection consisted of electrospray, negative-mode ionization tandem mass spectrometry in the multiple reaction monitoring (MRM) mode. The accuracy was 96.0-102.2%, and precision was 2.1-7.5% in the concentration range of 10-10 000 ng/mL. Recovery from plasma was 46.0-72.6%, and ion suppression was 9.8-25.7%. Plasma freeze/thaw stability was 87.5-104.3%, and stability for 4 h at room temperature was 98.7-100.0%. This assay is currently being used to quantitate 5-FU in human plasma samples.

Duke Scholars

Published In

Rapid Communications in Mass Spectrometry : Rcm

DOI

EISSN

1097-0231

ISSN

0951-4198

Publication Date

January 2008

Volume

22

Issue

2

Start / End Page

224 / 230

Related Subject Headings

  • Tandem Mass Spectrometry
  • Spectrometry, Mass, Electrospray Ionization
  • Reproducibility of Results
  • Middle Aged
  • Male
  • Humans
  • Fluorouracil
  • Chromatography, High Pressure Liquid
  • Antimetabolites, Antineoplastic
  • Analytical Chemistry
 

Citation

APA
Chicago
ICMJE
MLA
NLM
Kosovec, J. E., Egorin, M. J., Gjurich, S., & Beumer, J. H. (2008). Quantitation of 5-fluorouracil (5-FU) in human plasma by liquid chromatography/electrospray ionization tandem mass spectrometry. Rapid Communications in Mass Spectrometry : Rcm, 22(2), 224–230. https://doi.org/10.1002/rcm.3362
Kosovec, Juliann E., Merrill J. Egorin, Susanna Gjurich, and Jan H. Beumer. “Quantitation of 5-fluorouracil (5-FU) in human plasma by liquid chromatography/electrospray ionization tandem mass spectrometry.Rapid Communications in Mass Spectrometry : Rcm 22, no. 2 (January 2008): 224–30. https://doi.org/10.1002/rcm.3362.
Kosovec JE, Egorin MJ, Gjurich S, Beumer JH. Quantitation of 5-fluorouracil (5-FU) in human plasma by liquid chromatography/electrospray ionization tandem mass spectrometry. Rapid Communications in Mass Spectrometry : Rcm. 2008 Jan;22(2):224–30.
Kosovec, Juliann E., et al. “Quantitation of 5-fluorouracil (5-FU) in human plasma by liquid chromatography/electrospray ionization tandem mass spectrometry.Rapid Communications in Mass Spectrometry : Rcm, vol. 22, no. 2, Jan. 2008, pp. 224–30. Epmc, doi:10.1002/rcm.3362.
Kosovec JE, Egorin MJ, Gjurich S, Beumer JH. Quantitation of 5-fluorouracil (5-FU) in human plasma by liquid chromatography/electrospray ionization tandem mass spectrometry. Rapid Communications in Mass Spectrometry : Rcm. 2008 Jan;22(2):224–230.
Journal cover image

Published In

Rapid Communications in Mass Spectrometry : Rcm

DOI

EISSN

1097-0231

ISSN

0951-4198

Publication Date

January 2008

Volume

22

Issue

2

Start / End Page

224 / 230

Related Subject Headings

  • Tandem Mass Spectrometry
  • Spectrometry, Mass, Electrospray Ionization
  • Reproducibility of Results
  • Middle Aged
  • Male
  • Humans
  • Fluorouracil
  • Chromatography, High Pressure Liquid
  • Antimetabolites, Antineoplastic
  • Analytical Chemistry