Worldwide Variation in the Use of Nuclear Cardiology Camera Technology, Reconstruction Software, and Imaging Protocols.

Publication ,  Journal Article
Hirschfeld, CB; Mercuri, M; Pascual, TNB; Karthikeyan, G; Vitola, JV; Mahmarian, JJ; Better, N; Bouyoucef, SE; Hee-Seung Bom, H; Lele, V ...
Published in: JACC Cardiovasc Imaging
September 2021

OBJECTIVES: This study sought to describe worldwide variations in the use of myocardial perfusion imaging hardware, software, and imaging protocols and their impact on radiation effective dose (ED). BACKGROUND: Concerns about long-term effects of ionizing radiation have prompted efforts to identify strategies for dose optimization in myocardial perfusion scintigraphy. Studies have increasingly shown opportunities for dose reduction using newer technologies and optimized protocols. METHODS: Data were submitted voluntarily to the INCAPS (International Atomic Energy Agency Nuclear Cardiology Protocols Study) registry, a multinational, cross-sectional study comprising 7,911 imaging studies from 308 labs in 65 countries. The study compared regional use of camera technologies, advanced post-processing software, and protocol characteristics and analyzed the influence of each factor on ED. RESULTS: Cadmium-zinc-telluride and positron emission tomography (PET) cameras were used in 10% (regional range 0% to 26%) and 6% (regional range 0% to 17%) of studies worldwide. Attenuation correction was used in 26% of cases (range 10% to 57%), and advanced post-processing software was used in 38% of cases (range 26% to 64%). Stress-first single-photon emission computed tomography (SPECT) imaging comprised nearly 20% of cases from all world regions, except North America, where it was used in just 7% of cases. Factors associated with lower ED and odds ratio for achieving radiation dose ≤9 mSv included use of cadmium-zinc-telluride, PET, advanced post-processing software, and stress- or rest-only imaging. Overall, 39% of all studies (97% PET and 35% SPECT) were ≤9 mSv, while just 6% of all studies (32% PET and 4% SPECT) achieved a dose ≤3 mSv. CONCLUSIONS: Newer-technology cameras, advanced software, and stress-only protocols were associated with reduced ED, but worldwide adoption of these practices was generally low and varied significantly between regions. The implementation of dose-optimizing technologies and protocols offers an opportunity to reduce patient radiation exposure across all world regions.

Duke Scholars

Published In

JACC Cardiovasc Imaging

DOI

EISSN

1876-7591

Publication Date

September 2021

Volume

14

Issue

9

Start / End Page

1819 / 1828

Location

United States

Related Subject Headings

  • Tomography, X-Ray Computed
  • Tomography, Emission-Computed, Single-Photon
  • Technology
  • Software
  • Radiation Dosage
  • Predictive Value of Tests
  • Myocardial Perfusion Imaging
  • Humans
  • Cross-Sectional Studies
  • Cardiovascular System & Hematology
 

Citation

APA
Chicago
ICMJE
MLA
NLM
Hirschfeld, C. B., Mercuri, M., Pascual, T. N. B., Karthikeyan, G., Vitola, J. V., Mahmarian, J. J., … INCAPS Investigators Group. (2021). Worldwide Variation in the Use of Nuclear Cardiology Camera Technology, Reconstruction Software, and Imaging Protocols. JACC Cardiovasc Imaging, 14(9), 1819–1828. https://doi.org/10.1016/j.jcmg.2020.11.011
Hirschfeld, Cole B., Mathew Mercuri, Thomas N. B. Pascual, Ganesan Karthikeyan, João V. Vitola, John J. Mahmarian, Nathan Better, et al. “Worldwide Variation in the Use of Nuclear Cardiology Camera Technology, Reconstruction Software, and Imaging Protocols.JACC Cardiovasc Imaging 14, no. 9 (September 2021): 1819–28. https://doi.org/10.1016/j.jcmg.2020.11.011.
Hirschfeld CB, Mercuri M, Pascual TNB, Karthikeyan G, Vitola JV, Mahmarian JJ, et al. Worldwide Variation in the Use of Nuclear Cardiology Camera Technology, Reconstruction Software, and Imaging Protocols. JACC Cardiovasc Imaging. 2021 Sep;14(9):1819–28.
Hirschfeld, Cole B., et al. “Worldwide Variation in the Use of Nuclear Cardiology Camera Technology, Reconstruction Software, and Imaging Protocols.JACC Cardiovasc Imaging, vol. 14, no. 9, Sept. 2021, pp. 1819–28. Pubmed, doi:10.1016/j.jcmg.2020.11.011.
Hirschfeld CB, Mercuri M, Pascual TNB, Karthikeyan G, Vitola JV, Mahmarian JJ, Better N, Bouyoucef SE, Hee-Seung Bom H, Lele V, Magboo VPC, Alexánderson E, Allam AH, Al-Mallah MH, Dorbala S, Flotats A, Jerome S, Kaufmann PA, Luxenburg O, Shaw LJ, Underwood SR, Rehani MM, Paez D, Dondi M, Einstein AJ, INCAPS Investigators Group. Worldwide Variation in the Use of Nuclear Cardiology Camera Technology, Reconstruction Software, and Imaging Protocols. JACC Cardiovasc Imaging. 2021 Sep;14(9):1819–1828.
Journal cover image

Published In

JACC Cardiovasc Imaging

DOI

EISSN

1876-7591

Publication Date

September 2021

Volume

14

Issue

9

Start / End Page

1819 / 1828

Location

United States

Related Subject Headings

  • Tomography, X-Ray Computed
  • Tomography, Emission-Computed, Single-Photon
  • Technology
  • Software
  • Radiation Dosage
  • Predictive Value of Tests
  • Myocardial Perfusion Imaging
  • Humans
  • Cross-Sectional Studies
  • Cardiovascular System & Hematology