Variability in image quality and radiation dose within and across 97 medical facilities.

Publication ,  Journal Article
Smith, TB; Zhang, S; Erkanli, A; Frush, D; Samei, E
Published in: J Med Imaging (Bellingham)
September 2021

Purpose: To characterize variability in image quality and radiation dose across a large cohort of computed tomography (CT) examinations and identify the scan factors with the highest influence on the observed variabilities. Approach: This retrospective institutional-review-board-exempt investigation was performed on 87,629 chest and abdomen-pelvis CT scans acquired for 97 facilities from 2018 to 2019. Images were assessed in terms of noise, resolution, and dose metrics (global noise, frequency in which modulation transfer function is at 0.50, and volumetric CT dose index, respectively). The results were fit to linear mixed-effects models to quantify the variabilities as affected by scan parameters and settings and patient characteristics. A list of factors, ranked by t -value with p < 0.05 , was ascertained for each of the six mixed effects models. A type III p -value test was used to assess the influence of facility. Results: Across different facilities, image quality and dose were significantly different ( p < 0.05 ), with little correlation between their mean magnitudes and consistency (Pearson's correlation coefficient < 0.34 ). Scanner model, slice thickness, recon field-of-view and kernel, mAs, kVp, patient size, and centering were the most influential factors. The two body regions exhibited similar rankings of these factors for noise (Spearman's correlation coefficient = 0.76 ) and dose (Spearman's correlation coefficient = 0.86 ) but not for resolution (Spearman's correlation coefficient = 0.52 ). Conclusions: Clinical CT scans can vary in image quality and dose with broad implications for diagnostic utility and radiation burden. Average scan quality was not correlated with interpatient scan-quality consistency. For a given facility, this variability can be quite large, with magnitude differences across facilities. The knowledge of the most influential factors per body region may be used to better manage these variabilities within and across facilities.

Duke Scholars

Published In

J Med Imaging (Bellingham)

DOI

ISSN

2329-4302

Publication Date

September 2021

Volume

8

Issue

5

Start / End Page

052105

Location

United States

Related Subject Headings

  • 4003 Biomedical engineering
  • 3202 Clinical sciences
 

Citation

APA
Chicago
ICMJE
MLA
NLM
Smith, T. B., Zhang, S., Erkanli, A., Frush, D., & Samei, E. (2021). Variability in image quality and radiation dose within and across 97 medical facilities. J Med Imaging (Bellingham), 8(5), 052105. https://doi.org/10.1117/1.JMI.8.5.052105
Smith, Taylor B., Shuaiqi Zhang, Alaattin Erkanli, Donald Frush, and Ehsan Samei. “Variability in image quality and radiation dose within and across 97 medical facilities.J Med Imaging (Bellingham) 8, no. 5 (September 2021): 052105. https://doi.org/10.1117/1.JMI.8.5.052105.
Smith TB, Zhang S, Erkanli A, Frush D, Samei E. Variability in image quality and radiation dose within and across 97 medical facilities. J Med Imaging (Bellingham). 2021 Sep;8(5):052105.
Smith, Taylor B., et al. “Variability in image quality and radiation dose within and across 97 medical facilities.J Med Imaging (Bellingham), vol. 8, no. 5, Sept. 2021, p. 052105. Pubmed, doi:10.1117/1.JMI.8.5.052105.
Smith TB, Zhang S, Erkanli A, Frush D, Samei E. Variability in image quality and radiation dose within and across 97 medical facilities. J Med Imaging (Bellingham). 2021 Sep;8(5):052105.

Published In

J Med Imaging (Bellingham)

DOI

ISSN

2329-4302

Publication Date

September 2021

Volume

8

Issue

5

Start / End Page

052105

Location

United States

Related Subject Headings

  • 4003 Biomedical engineering
  • 3202 Clinical sciences