Correction for Systematic Bias in Radiomics Measurements Due to Variation in Imaging Protocols.
RATIONALE AND OBJECTIVES: The accuracy of measured radiomics features is affected by CT imaging protocols. This study aims to ascertain if applying bias corrections can improve the classification performance of the radiomics features. MATERIALS AND METHODS: A cohort of 144 Non-Small Cell Lung Cancer patient CT images was used to calculate radiomics features for use in predictive models of patient pathological stage. Simulation models of the tumors, matched to patient lesion qualities of size, contrast, and degree of spiculation, were used to both create and assess protocol-specific correction factors. The usefulness of correction was first assessed by applying the corrections to simulated lesion phantoms with known properties using a corrected paired Student's t-test. The sensitivity of radiomics features to correction factors was assessed by applying a library of possible theoretical correction factors to the uncorrected radiomics from the patient data. The data were then used to assess the effect of the correction on prediction performance (AUC) from a logistic regression radiomics model across the patient cases. RESULTS: The correction factors were shown to reduce the bias of radiomics features, caused by protocols, provided that the correction factors were derived from lesion models with similar properties. The sensitivity of the radiomics features to changes due to protocol effects was on average 89% among all features. The corrections applied to patient data resulted in a small increase of 0.0074 in AUC that was not statistically significant (p=0.60). CONCLUSION: Protocol-specific correction factors can be applied to radiomics studies to control for biases introduced by different imaging protocols. The correction factors should ideally be lesion-specific, derived using lesion models that echo patient lesion characteristics in terms of size, contrast, and degree of spiculation. Small corrections in the 10% range offers only a small improvement in the predictability of radiomics.
Duke Scholars
Altmetric Attention Stats
Dimensions Citation Stats
Published In
DOI
EISSN
Publication Date
Volume
Issue
Start / End Page
Location
Related Subject Headings
- Tomography, X-Ray Computed
- Retrospective Studies
- Nuclear Medicine & Medical Imaging
- Lung Neoplasms
- Humans
- Carcinoma, Non-Small-Cell Lung
- Bias
- 3202 Clinical sciences
- 1103 Clinical Sciences
Citation
Published In
DOI
EISSN
Publication Date
Volume
Issue
Start / End Page
Location
Related Subject Headings
- Tomography, X-Ray Computed
- Retrospective Studies
- Nuclear Medicine & Medical Imaging
- Lung Neoplasms
- Humans
- Carcinoma, Non-Small-Cell Lung
- Bias
- 3202 Clinical sciences
- 1103 Clinical Sciences