Skip to main content

Evaluation of a Digital Handheld Hydrogen Breath Monitor to Diagnose Lactose Malabsorption: Interventional Crossover Study.

Publication ,  Journal Article
Mathews, SC; Templeton, S; Taylor, SK; Harris, S; Stewart, M; Raja, SM
Published in: JMIR Form Res
October 18, 2021

BACKGROUND: Lactose malabsorption is a common condition that affects a broad segment of the population. Clinical diagnosis based on symptom recall can be unreliable and conventional testing can be inconvenient, requiring expensive laboratory-based equipment and conduction of the testing in a clinical setting. OBJECTIVE: The aim of this study is to assess the performance of a digital handheld hydrogen breath monitor (GIMate) in diagnosing lactose malabsorption compared to a US Food and Drug Administration (FDA)-cleared device (H2 Check) for the same indication. METHODS: An interventional crossover study was performed in adult participants with a prior confirmed diagnosis of lactose malabsorption or a suspected history of lactose intolerance. RESULTS: A total of 31 participants (mean age 33.9 years) were enrolled in the study. There was 100% positive percent agreement and 100% negative percent agreement between the GIMate monitor and the H2 Check. Correlation between gastrointestinal symptoms and hydrogen values was positive at 0.82 (P<.001). CONCLUSIONS: The digital handheld GIMate breath monitor achieved equivalent diagnostic performance to that of an FDA-cleared device in the diagnosis of lactose malabsorption. TRIAL REGISTRATION: ClinicalTrials.gov NCT04754724; https://clinicaltrials.gov/ct2/show/NCT04754724.

Duke Scholars

Published In

JMIR Form Res

DOI

EISSN

2561-326X

Publication Date

October 18, 2021

Volume

5

Issue

10

Start / End Page

e33009

Location

Canada

Related Subject Headings

  • 42 Health sciences
  • 32 Biomedical and clinical sciences
 

Citation

APA
Chicago
ICMJE
MLA
NLM
Mathews, S. C., Templeton, S., Taylor, S. K., Harris, S., Stewart, M., & Raja, S. M. (2021). Evaluation of a Digital Handheld Hydrogen Breath Monitor to Diagnose Lactose Malabsorption: Interventional Crossover Study. JMIR Form Res, 5(10), e33009. https://doi.org/10.2196/33009
Mathews, Simon C., Sandy Templeton, Stephanie K. Taylor, Sten Harris, Margaret Stewart, and Shruti M. Raja. “Evaluation of a Digital Handheld Hydrogen Breath Monitor to Diagnose Lactose Malabsorption: Interventional Crossover Study.JMIR Form Res 5, no. 10 (October 18, 2021): e33009. https://doi.org/10.2196/33009.
Mathews SC, Templeton S, Taylor SK, Harris S, Stewart M, Raja SM. Evaluation of a Digital Handheld Hydrogen Breath Monitor to Diagnose Lactose Malabsorption: Interventional Crossover Study. JMIR Form Res. 2021 Oct 18;5(10):e33009.
Mathews, Simon C., et al. “Evaluation of a Digital Handheld Hydrogen Breath Monitor to Diagnose Lactose Malabsorption: Interventional Crossover Study.JMIR Form Res, vol. 5, no. 10, Oct. 2021, p. e33009. Pubmed, doi:10.2196/33009.
Mathews SC, Templeton S, Taylor SK, Harris S, Stewart M, Raja SM. Evaluation of a Digital Handheld Hydrogen Breath Monitor to Diagnose Lactose Malabsorption: Interventional Crossover Study. JMIR Form Res. 2021 Oct 18;5(10):e33009.

Published In

JMIR Form Res

DOI

EISSN

2561-326X

Publication Date

October 18, 2021

Volume

5

Issue

10

Start / End Page

e33009

Location

Canada

Related Subject Headings

  • 42 Health sciences
  • 32 Biomedical and clinical sciences