Scanner-specific validation of a CT simulator using a COPD-emulated anthropomorphic phantom.

Publication ,  Journal Article
Shankar, SS; Jadick, GL; Hoffman, EA; Atha, J; Sieren, JC; Samei, E; Abadi, E
Published in: Proc SPIE Int Soc Opt Eng
2022

Traditional methods of quantitative analysis of CT images typically involve working with patient data, which is often expensive and limited in terms of ground truth. To counter these restrictions, quantitative assessments can instead be made through Virtual Imaging Trials (VITs) which simulate the CT imaging process. This study sought to validate DukeSim (a scanner-specific CT simulator) utilizing clinically relevant biomarkers for a customized anthropomorphic chest phantom. The physical phantom was imaged utilizing two commercial CT scanners (Siemens Somatom Force and Definition Flash) with varying imaging parameters. A computational version of the phantom was simulated utilizing DukeSim for each corresponding real acquisition. Biomarkers were computed and compared between the real and virtually acquired CT images to assess the validity of DukeSim. The simulated images closely matched the real images both qualitatively and quantitatively, with the average biomarker percent difference of 3.84% (range 0.19% to 18.27%). Results showed that DukeSim is reasonably well validated across various patient imaging conditions and scanners, which indicates the utility of DukeSim for further VIT studies where real patient data may not be feasible.

Duke Scholars

Published In

Proc SPIE Int Soc Opt Eng

DOI

ISSN

0277-786X

Publication Date

2022

Volume

12031

Location

United States

Related Subject Headings

  • 5102 Atomic, molecular and optical physics
  • 4009 Electronics, sensors and digital hardware
  • 4006 Communications engineering
 

Citation

APA
Chicago
ICMJE
MLA
NLM
Shankar, S. S., Jadick, G. L., Hoffman, E. A., Atha, J., Sieren, J. C., Samei, E., & Abadi, E. (2022). Scanner-specific validation of a CT simulator using a COPD-emulated anthropomorphic phantom. Proc SPIE Int Soc Opt Eng, 12031. https://doi.org/10.1117/12.2613212
Shankar, Sachin S., Giavanna L. Jadick, Eric A. Hoffman, Jarron Atha, Jessica C. Sieren, Ehsan Samei, and Ehsan Abadi. “Scanner-specific validation of a CT simulator using a COPD-emulated anthropomorphic phantom.Proc SPIE Int Soc Opt Eng 12031 (2022). https://doi.org/10.1117/12.2613212.
Shankar SS, Jadick GL, Hoffman EA, Atha J, Sieren JC, Samei E, et al. Scanner-specific validation of a CT simulator using a COPD-emulated anthropomorphic phantom. Proc SPIE Int Soc Opt Eng. 2022;12031.
Shankar, Sachin S., et al. “Scanner-specific validation of a CT simulator using a COPD-emulated anthropomorphic phantom.Proc SPIE Int Soc Opt Eng, vol. 12031, 2022. Pubmed, doi:10.1117/12.2613212.
Shankar SS, Jadick GL, Hoffman EA, Atha J, Sieren JC, Samei E, Abadi E. Scanner-specific validation of a CT simulator using a COPD-emulated anthropomorphic phantom. Proc SPIE Int Soc Opt Eng. 2022;12031.

Published In

Proc SPIE Int Soc Opt Eng

DOI

ISSN

0277-786X

Publication Date

2022

Volume

12031

Location

United States

Related Subject Headings

  • 5102 Atomic, molecular and optical physics
  • 4009 Electronics, sensors and digital hardware
  • 4006 Communications engineering