Skip to main content
Journal cover image

Point-of-care vertical flow immunoassay system for ultra-sensitive multiplex biothreat-agent detection in biological fluids.

Publication ,  Journal Article
Devadhasan, JP; Summers, AJ; Gu, J; Smith, S; Thomas, B; Fattahi, A; Helton, J; Pandit, SG; Gates-Hollingsworth, M; Hau, D; Pflughoeft, KJ ...
Published in: Biosensors & bioelectronics
January 2023

This paper presents simple, fast, and sensitive detection of multiple biothreat agents by paper-based vertical flow colorimetric sandwich immunoassay for detection of Yersinia pestis (LcrV and F1) and Francisella tularensis (lipopolysaccharide; LPS) antigens using a vertical flow immunoassay (VFI) prototype with portable syringe pump and a new membrane holder. The capture antibody (cAb) printing onto nitrocellulose membrane and gold-labelled detection antibody (dAb) were optimized to enhance the assay sensitivity and specificity. Even though the paper pore size was relaxed from previous 0.1 μm to the current 0.45 μm for serum samples, detection limits as low as 0.050 ng/mL for LcrV and F1, and 0.100 ng/mL for FtLPS have been achieved in buffer and similarly in diluted serum (with LcrV and F1 LODs remained the same and LPS LOD reduced to 0.250 ng/mL). These were 40, 80, and 50X (20X for LPS in serum) better than those from lateral flow configuration. Furthermore, the comparison of multiplex format demonstrated low cross-reactivity and equal sensitivity to that of the singleplex assay. The optimized VFI platform thus provides a portable and rapid on-site monitoring system for multiplex biothreat detection with the potential for high sensitivity, specificity, reproducibility, and multiplexing capability, supporting its utility in remote and resource-limited settings.

Duke Scholars

Altmetric Attention Stats
Dimensions Citation Stats

Published In

Biosensors & bioelectronics

DOI

EISSN

1873-4235

ISSN

0956-5663

Publication Date

January 2023

Volume

219

Start / End Page

114796

Related Subject Headings

  • Bioinformatics
  • 4018 Nanotechnology
  • 4003 Biomedical engineering
  • 3401 Analytical chemistry
  • 1007 Nanotechnology
  • 0903 Biomedical Engineering
  • 0301 Analytical Chemistry
 

Citation

APA
Chicago
ICMJE
MLA
NLM
Devadhasan, J. P., Summers, A. J., Gu, J., Smith, S., Thomas, B., Fattahi, A., … Zenhausern, F. (2023). Point-of-care vertical flow immunoassay system for ultra-sensitive multiplex biothreat-agent detection in biological fluids. Biosensors & Bioelectronics, 219, 114796. https://doi.org/10.1016/j.bios.2022.114796
Devadhasan, Jasmine Pramila, Alexander Jarrett Summers, Jian Gu, Stanley Smith, Baiju Thomas, Ali Fattahi, James Helton, et al. “Point-of-care vertical flow immunoassay system for ultra-sensitive multiplex biothreat-agent detection in biological fluids.Biosensors & Bioelectronics 219 (January 2023): 114796. https://doi.org/10.1016/j.bios.2022.114796.
Devadhasan JP, Summers AJ, Gu J, Smith S, Thomas B, Fattahi A, et al. Point-of-care vertical flow immunoassay system for ultra-sensitive multiplex biothreat-agent detection in biological fluids. Biosensors & bioelectronics. 2023 Jan;219:114796.
Devadhasan, Jasmine Pramila, et al. “Point-of-care vertical flow immunoassay system for ultra-sensitive multiplex biothreat-agent detection in biological fluids.Biosensors & Bioelectronics, vol. 219, Jan. 2023, p. 114796. Epmc, doi:10.1016/j.bios.2022.114796.
Devadhasan JP, Summers AJ, Gu J, Smith S, Thomas B, Fattahi A, Helton J, Pandit SG, Gates-Hollingsworth M, Hau D, Pflughoeft KJ, Montgomery DC, Atta S, Vo-Dinh T, AuCoin D, Zenhausern F. Point-of-care vertical flow immunoassay system for ultra-sensitive multiplex biothreat-agent detection in biological fluids. Biosensors & bioelectronics. 2023 Jan;219:114796.
Journal cover image

Published In

Biosensors & bioelectronics

DOI

EISSN

1873-4235

ISSN

0956-5663

Publication Date

January 2023

Volume

219

Start / End Page

114796

Related Subject Headings

  • Bioinformatics
  • 4018 Nanotechnology
  • 4003 Biomedical engineering
  • 3401 Analytical chemistry
  • 1007 Nanotechnology
  • 0903 Biomedical Engineering
  • 0301 Analytical Chemistry