Closed-loop optimal and automatic tuning of pulse amplitude and width in EMG-guided controllable transcranial magnetic stimulation

Publication ,  Journal Article
Alavi, SMM; Vila-Rodriguez, F; Mahdi, A; Goetz, SM
Published in: Biomedical Engineering Letters
May 1, 2023

This paper proposes an efficient algorithm for automatic and optimal tuning of pulse amplitude and width for sequential parameter estimation (SPE) of the neural membrane time constant and input–output (IO) curve parameters in closed-loop electromyography-guided (EMG-guided) controllable transcranial magnetic stimulation (cTMS). The proposed SPE is performed by administering a train of optimally tuned TMS pulses and updating the estimations until a stopping rule is satisfied or the maximum number of pulses is reached. The pulse amplitude is computed by the Fisher information maximization. The pulse width is chosen by maximizing a normalized depolarization factor, which is defined to separate the optimization and tuning of the pulse amplitude and width. The normalized depolarization factor maximization identifies the critical pulse width, which is an important parameter in the identifiability analysis, without any prior neurophysiological or anatomical knowledge of the neural membrane. The effectiveness of the proposed algorithm is evaluated through simulation. The results confirm satisfactory estimation of the membrane time constant and IO curve parameters for the simulation case. By defining the stopping rule based on the satisfaction of the convergence criterion with tolerance of 0.01 for 5 consecutive times for all parameters, the IO curve parameters are estimated with 52 TMS pulses, with absolute relative estimation errors (AREs) of less than 7%. The membrane time constant is estimated with 0.67% ARE, and the pulse width value tends to the critical pulse width with 0.16% ARE with 52 TMS pulses. The results confirm that the pulse width and amplitude can be tuned optimally and automatically to estimate the membrane time constant and IO curve parameters in real-time with closed-loop EMG-guided cTMS.

Duke Scholars

Published In

Biomedical Engineering Letters

DOI

EISSN

2093-985X

ISSN

2093-9868

Publication Date

May 1, 2023

Volume

13

Issue

2

Start / End Page

119 / 127
 

Citation

APA
Chicago
ICMJE
MLA
NLM
Alavi, S. M. M., Vila-Rodriguez, F., Mahdi, A., & Goetz, S. M. (2023). Closed-loop optimal and automatic tuning of pulse amplitude and width in EMG-guided controllable transcranial magnetic stimulation. Biomedical Engineering Letters, 13(2), 119–127. https://doi.org/10.1007/s13534-022-00259-3
Alavi, S. M. M., F. Vila-Rodriguez, A. Mahdi, and S. M. Goetz. “Closed-loop optimal and automatic tuning of pulse amplitude and width in EMG-guided controllable transcranial magnetic stimulation.” Biomedical Engineering Letters 13, no. 2 (May 1, 2023): 119–27. https://doi.org/10.1007/s13534-022-00259-3.
Alavi SMM, Vila-Rodriguez F, Mahdi A, Goetz SM. Closed-loop optimal and automatic tuning of pulse amplitude and width in EMG-guided controllable transcranial magnetic stimulation. Biomedical Engineering Letters. 2023 May 1;13(2):119–27.
Alavi, S. M. M., et al. “Closed-loop optimal and automatic tuning of pulse amplitude and width in EMG-guided controllable transcranial magnetic stimulation.” Biomedical Engineering Letters, vol. 13, no. 2, May 2023, pp. 119–27. Scopus, doi:10.1007/s13534-022-00259-3.
Alavi SMM, Vila-Rodriguez F, Mahdi A, Goetz SM. Closed-loop optimal and automatic tuning of pulse amplitude and width in EMG-guided controllable transcranial magnetic stimulation. Biomedical Engineering Letters. 2023 May 1;13(2):119–127.
Journal cover image

Published In

Biomedical Engineering Letters

DOI

EISSN

2093-985X

ISSN

2093-9868

Publication Date

May 1, 2023

Volume

13

Issue

2

Start / End Page

119 / 127