Skip to main content
Journal cover image

Improvement of the Applicability, Efficiency, andPrecision of the Penning Trap Mass Spectrometer ISOLTRAP

Publication ,  Journal Article
Kellerbauer, A; Bollen, G; Dilling, J; Henry, S; Herfurth, F; Kluge, HJ; Lamour, E; Lunney, D; Moore, RB; Scheidenberger, C; Schwarz, S ...
Published in: Hyperfine Interactions
January 28, 2001

With the Penning trap mass spectrometer ISOLTRAP, close to 200 nuclides have already been investigated and their masses determined with a typical relative precision of δm/m=10−7. Recently, ISOLTRAP's beam preparation system was replaced by an RFQ ion beam cooler and buncher. The principle and the characteristics of this new beam preparation system will be presented. It is planned to use ions of various carbon clusters C+n (n>1) as reference ions for mass measurements. Apart from negligible molecular binding energies, these clusters have masses that are exact multiples of the unified atomic mass unit. This will allow ISOLTRAP to carry out absolute mass measurements as well as to investigate possible mass-dependent systematic errors. The results of tests of the production, transport, and trapping of such carbon clusters will be presented.

Duke Scholars

Published In

Hyperfine Interactions

DOI

ISSN

0304-3843

Publication Date

January 28, 2001

Volume

132

Issue

1-4

Start / End Page

507 / 511

Related Subject Headings

  • General Physics
  • 5106 Nuclear and plasma physics
  • 5104 Condensed matter physics
  • 5102 Atomic, molecular and optical physics
  • 0204 Condensed Matter Physics
  • 0202 Atomic, Molecular, Nuclear, Particle and Plasma Physics
 

Citation

APA
Chicago
ICMJE
MLA
NLM
Kellerbauer, A., Bollen, G., Dilling, J., Henry, S., Herfurth, F., Kluge, H. J., … Szerypo, J. (2001). Improvement of the Applicability, Efficiency, andPrecision of the Penning Trap Mass Spectrometer ISOLTRAP. Hyperfine Interactions, 132(1–4), 507–511. https://doi.org/10.1023/A:1011991316760
Kellerbauer, A., G. Bollen, J. Dilling, S. Henry, F. Herfurth, H. J. Kluge, E. Lamour, et al. “Improvement of the Applicability, Efficiency, andPrecision of the Penning Trap Mass Spectrometer ISOLTRAP.” Hyperfine Interactions 132, no. 1–4 (January 28, 2001): 507–11. https://doi.org/10.1023/A:1011991316760.
Kellerbauer A, Bollen G, Dilling J, Henry S, Herfurth F, Kluge HJ, et al. Improvement of the Applicability, Efficiency, andPrecision of the Penning Trap Mass Spectrometer ISOLTRAP. Hyperfine Interactions. 2001 Jan 28;132(1–4):507–11.
Kellerbauer, A., et al. “Improvement of the Applicability, Efficiency, andPrecision of the Penning Trap Mass Spectrometer ISOLTRAP.” Hyperfine Interactions, vol. 132, no. 1–4, Jan. 2001, pp. 507–11. Scopus, doi:10.1023/A:1011991316760.
Kellerbauer A, Bollen G, Dilling J, Henry S, Herfurth F, Kluge HJ, Lamour E, Lunney D, Moore RB, Scheidenberger C, Schwarz S, Sikler G, Szerypo J. Improvement of the Applicability, Efficiency, andPrecision of the Penning Trap Mass Spectrometer ISOLTRAP. Hyperfine Interactions. 2001 Jan 28;132(1–4):507–511.
Journal cover image

Published In

Hyperfine Interactions

DOI

ISSN

0304-3843

Publication Date

January 28, 2001

Volume

132

Issue

1-4

Start / End Page

507 / 511

Related Subject Headings

  • General Physics
  • 5106 Nuclear and plasma physics
  • 5104 Condensed matter physics
  • 5102 Atomic, molecular and optical physics
  • 0204 Condensed Matter Physics
  • 0202 Atomic, Molecular, Nuclear, Particle and Plasma Physics