Can Patient-Reported Outcome Measurement Information System Measures Estimate High Impact Chronic Pain After Total Joint Arthroplasty?
BACKGROUND: High impact chronic pain (HICP) is not typically measured following orthopedic surgeries, but has a substantial negative impact on postoperative quality of life. This analysis determined which Patient-Reported Outcome Measurement Information System (PROMIS) measures accurately estimate HICP status following total joint arthroplasty (TJA). METHODS: This was a secondary analysis of a hip and knee TJA cohort. HICP status was determined by two items from the Graded Chronic Pain Scale-Revised. The cohort (n = 2,400) consisted of 47.5% hip (n = 1,142) and 52.5% knee TJA (n = 1,258). For total hip arthroplasty (THA), 53.7% were women (n = 615), 48.6% were 65 years or older (n = 557), 72.5% completed the survey more than 24 months after first surgery (n = 831), and 9.9% had HICP (n = 114). For total knee arthroplasty (TKA), 54.3% were women (n = 687), 59.3% were 65 years or older (n = 750), 72.3% survey completed the survey more than 24 months after first surgery (n = 915), and 11.5% had HICP (n = 145). Included PROMIS measures were pain interference, physical function, anxiety, and sleep disturbance. First, discriminant function analysis determined PROMIS measure contribution to HICP status. Then, area under the curve (AUC) calculated the accuracy of PROMIS measures to estimate HICP status. Influences of sociodemographic and surgical characteristics on AUC were explored in sensitivity analyses. RESULTS: Results for TKA and THA were similar so they are presented collectively for the sake of brevity. Mean differences were identified for all PROMIS measures for those with HICP (All P values < 0.01). Pain interference (β = 0.934) and sleep disturbance (β = 0.154) were independently correlated with HICP status in discriminant function analyses. The AUC (95% CIs) for HICP were as follows: pain interference (.952-.973), physical function (.921-.949), sleep (.780-.838), and anxiety (.687-.757). Sensitivity analyses revealed little change in AUC and HICP cutoff scores for PROMIS pain interference and physical function. CONCLUSION: Two PROMIS measures commonly administered as standard of care for orthopedics, pain interference, and physical function, can be used to estimate HICP status for THA and TKA, thereby refining assessment of TJA outcomes.
Duke Scholars
Published In
DOI
EISSN
Publication Date
Volume
Issue
Start / End Page
Location
Related Subject Headings
- Quality of Life
- Patient Reported Outcome Measures
- Orthopedics
- Male
- Humans
- Female
- Chronic Pain
- Arthroplasty, Replacement, Knee
- Arthroplasty, Replacement, Hip
- 4003 Biomedical engineering
Citation
Published In
DOI
EISSN
Publication Date
Volume
Issue
Start / End Page
Location
Related Subject Headings
- Quality of Life
- Patient Reported Outcome Measures
- Orthopedics
- Male
- Humans
- Female
- Chronic Pain
- Arthroplasty, Replacement, Knee
- Arthroplasty, Replacement, Hip
- 4003 Biomedical engineering