Three-dimensional analysis of anterior talofibular ligament strain patterns during cadaveric ankle motion using a miniaturized ligament performance probe.

Publication ,  Journal Article
Takeuchi, Y; Inokuchi, R; Takao, M; Glazebrook, M; Martin Oliva, X; Yamazaki, T; Kubo, M; Lowe, D; Matsui, K; Katakura, M; Ozeki, S ...
Published in: BMC Musculoskelet Disord
February 20, 2021

BACKGROUND: Measuring the strain patterns of ligaments at various joint positions informs our understanding of their function. However, few studies have examined the biomechanical properties of ankle ligaments; further, the tensile properties of each ligament, during motion, have not been described. This limitation exists because current biomechanical sensors are too big to insert within the ankle. The present study aimed to validate a novel miniaturized ligament performance probe (MLPP) system for measuring the strain patterns of the anterior talofibular ligament (ATFL) during ankle motion. METHODS: Six fresh-frozen, through-the-knee, lower extremity, cadaveric specimens were used to conduct this study. An MLPP system, comprising a commercially available strain gauge (force probe), amplifier unit, display unit, and logger, was sutured into the midsubstance of the ATFL fibers. To measure tensile forces, a round, metal disk (a "clock", 150 mm in diameter) was affixed to the plantar aspect of each foot. With a 1.2-Nm load applied to the ankle and subtalar joint complex, the ankle was manually moved from 15° dorsiflexion to 30° plantar flexion. The clock was rotated in 30° increments to measure the ATFL strain detected at each endpoint by the miniature force probe. Individual strain data were aligned with the neutral (0) position value; the maximum value was 100. RESULTS: Throughout the motion required to shift from 15° dorsiflexion to 30° plantar flexion, the ATFL tensed near 20° (plantar flexion), and the strain increased as the plantar flexion angle increased. The ATFL was maximally tensioned at the 2 and 3 o'clock (inversion) positions (96.0 ± 5.8 and 96.3 ± 5.7) and declined sharply towards the 7 o'clock position (12.4 ± 16.8). Within the elastic range of the ATFL (the range within which it can return to its original shape and length), the tensile force was proportional to the strain, in all specimens. CONCLUSION: The MLPP system is capable of measuring ATFL strain patterns; thus, this system may be used to effectively determine the relationship between limb position and ATFL ankle ligament strain patterns.

Duke Scholars

Published In

BMC Musculoskelet Disord

DOI

EISSN

1471-2474

Publication Date

February 20, 2021

Volume

22

Issue

1

Start / End Page

208

Location

England

Related Subject Headings

  • Orthopedics
  • Lateral Ligament, Ankle
  • Joint Instability
  • Humans
  • Cadaver
  • Biomechanical Phenomena
  • Ankle Joint
  • Ankle
  • 4207 Sports science and exercise
  • 4201 Allied health and rehabilitation science
 

Citation

APA
Chicago
ICMJE
MLA
NLM
Takeuchi, Y., Inokuchi, R., Takao, M., Glazebrook, M., Martin Oliva, X., Yamazaki, T., … Ankle Instability Group. (2021). Three-dimensional analysis of anterior talofibular ligament strain patterns during cadaveric ankle motion using a miniaturized ligament performance probe. BMC Musculoskelet Disord, 22(1), 208. https://doi.org/10.1186/s12891-021-04058-2
Takeuchi, Yoshitaka, Ryota Inokuchi, Masato Takao, Mark Glazebrook, Xavier Martin Oliva, Takayuki Yamazaki, Maya Kubo, et al. “Three-dimensional analysis of anterior talofibular ligament strain patterns during cadaveric ankle motion using a miniaturized ligament performance probe.BMC Musculoskelet Disord 22, no. 1 (February 20, 2021): 208. https://doi.org/10.1186/s12891-021-04058-2.
Takeuchi Y, Inokuchi R, Takao M, Glazebrook M, Martin Oliva X, Yamazaki T, et al. Three-dimensional analysis of anterior talofibular ligament strain patterns during cadaveric ankle motion using a miniaturized ligament performance probe. BMC Musculoskelet Disord. 2021 Feb 20;22(1):208.
Takeuchi, Yoshitaka, et al. “Three-dimensional analysis of anterior talofibular ligament strain patterns during cadaveric ankle motion using a miniaturized ligament performance probe.BMC Musculoskelet Disord, vol. 22, no. 1, Feb. 2021, p. 208. Pubmed, doi:10.1186/s12891-021-04058-2.
Takeuchi Y, Inokuchi R, Takao M, Glazebrook M, Martin Oliva X, Yamazaki T, Kubo M, Lowe D, Matsui K, Katakura M, Ozeki S, Ankle Instability Group. Three-dimensional analysis of anterior talofibular ligament strain patterns during cadaveric ankle motion using a miniaturized ligament performance probe. BMC Musculoskelet Disord. 2021 Feb 20;22(1):208.
Journal cover image

Published In

BMC Musculoskelet Disord

DOI

EISSN

1471-2474

Publication Date

February 20, 2021

Volume

22

Issue

1

Start / End Page

208

Location

England

Related Subject Headings

  • Orthopedics
  • Lateral Ligament, Ankle
  • Joint Instability
  • Humans
  • Cadaver
  • Biomechanical Phenomena
  • Ankle Joint
  • Ankle
  • 4207 Sports science and exercise
  • 4201 Allied health and rehabilitation science