Testing of an intrathoracic artificial lung in a pig model.

Publication ,  Journal Article
Cook, KE; Makarewicz, AJ; Backer, CL; Mockros, LF; Przybylo, HJ; Crawford, SE; Hernandez, JM; Leonard, RJ; Mavroudis, C
Published in: ASAIO J
1996

A low input impedance, intrathoracic artificial lung is being developed for use in acute respiratory failure or as a bridge to transplantation. The device uses microporous, hollow fibers in a 0.74 void fraction, 1.83 m2 surface area bundle. The bundle is placed within a thermoformed polyethylene terephthalate glucose modified housing with a gross volume of 800 cm3. The blood inlet and outlet are 18 mm inner diameter vascular grafts. Between the inlet graft and the device is a 1 inch inner diameter, thin-walled, latex tubing compliance chamber. These devices were implanted in Yorkshire pigs via median sternotomy with an end to side anastomosis to the pulmonary artery and left atrium. The distal pulmonary artery was occluded to divert the right ventricular output to the device. Pigs 1 and 2 were supported fully for 24 hrs and then killed. Pig 3 was supported partially for 20 hrs and died from bleeding complications. The first implant, in a 55 kg male pig, transferred an average of 176 ml/min +/- 42.4 of O2 and 190 ml/min +/- 39.7 of CO2 with an average blood flow rate of 2.71/min +/- 0.46. The normalized average right ventricular output power, Pn, was 0.062 W/(L/min) +/- 0.0082, and the average device resistance, R, was 3.5 mmHg/(L/min) +/- 0.62. The second implant, in a 60 kg male pig, transferred an average of 204 ml/min +/- 22.5 of O2 and 242 ml/min +/- 17.2 of CO2 with an average blood flow rate of 3.7 L/min +/- 0.45, Pn of 0.064 W/(L/min) +/- 0.0067, and R of 4.3 mmHg/(L/min) +/- 0.89. The third implant, in an 89 kg male pig, transferred an average of 156 ml/min +/- 39.6 of O2 and 187 ml/min +/- 21.4 of CO2 with an average blood flow rate of 2.5 L/min +/- 0.49, Pn of 0.052 W/(l/min) +/- 0.0067, and R of 3.4 mmHg/(L/min) +/- 0.74. These experiments suggest that such an artificial lung can temporarily support the gas transfer requirements of adult humans without over-loading the right ventricle.

Duke Scholars

Published In

ASAIO J

DOI

ISSN

1058-2916

Publication Date

1996

Volume

42

Issue

5

Start / End Page

M604 / M609

Location

United States

Related Subject Headings

  • Thorax
  • Swine
  • Respiratory Insufficiency
  • Respiratory Distress Syndrome
  • Pulmonary Gas Exchange
  • Male
  • Lung
  • Humans
  • Hemodynamics
  • Evaluation Studies as Topic
 

Citation

APA
Chicago
ICMJE
MLA
NLM
Cook, K. E., Makarewicz, A. J., Backer, C. L., Mockros, L. F., Przybylo, H. J., Crawford, S. E., … Mavroudis, C. (1996). Testing of an intrathoracic artificial lung in a pig model. ASAIO J, 42(5), M604–M609. https://doi.org/10.1097/00002480-199609000-00059
Cook, K. E., A. J. Makarewicz, C. L. Backer, L. F. Mockros, H. J. Przybylo, S. E. Crawford, J. M. Hernandez, R. J. Leonard, and C. Mavroudis. “Testing of an intrathoracic artificial lung in a pig model.ASAIO J 42, no. 5 (1996): M604–9. https://doi.org/10.1097/00002480-199609000-00059.
Cook KE, Makarewicz AJ, Backer CL, Mockros LF, Przybylo HJ, Crawford SE, et al. Testing of an intrathoracic artificial lung in a pig model. ASAIO J. 1996;42(5):M604–9.
Cook, K. E., et al. “Testing of an intrathoracic artificial lung in a pig model.ASAIO J, vol. 42, no. 5, 1996, pp. M604–09. Pubmed, doi:10.1097/00002480-199609000-00059.
Cook KE, Makarewicz AJ, Backer CL, Mockros LF, Przybylo HJ, Crawford SE, Hernandez JM, Leonard RJ, Mavroudis C. Testing of an intrathoracic artificial lung in a pig model. ASAIO J. 1996;42(5):M604–M609.

Published In

ASAIO J

DOI

ISSN

1058-2916

Publication Date

1996

Volume

42

Issue

5

Start / End Page

M604 / M609

Location

United States

Related Subject Headings

  • Thorax
  • Swine
  • Respiratory Insufficiency
  • Respiratory Distress Syndrome
  • Pulmonary Gas Exchange
  • Male
  • Lung
  • Humans
  • Hemodynamics
  • Evaluation Studies as Topic