Skip to main content

Agreement between semiautomatic and manual measurement of selected parameters on weight-bearing computed tomography images in total ankle replacement: a retrospective study

Publication ,  Journal Article
Mallavarapu, V; Jasper, R; Jones, M; VandeLune, C; Alencar Mendes de Carvalho, K; Chun Kim, K; Barbachan Mansur, NS; Dibbern, K; De César Netto, C
Published in: Journal of the Foot & Ankle
April 30, 2022

Objective: To assess the agreement between semiautomatic 3D measurements and manual measurements derived from WBCT images in patients with end-stage ankle osteoarthritis (AO) who underwent total ankle replacement (TAR). Methods: In this retrospective, IRB-approved study (ID #201904825), we evaluated patients who underwent TAR via the lateral trans-fibular approach for end-stage ankle OA. The study included 14 ankles from 14 patients. Raw multiplanar data were analyzed using CubeVue® software. Lateral talar station (LTS) was obtained in the sagittal plane, while hindfoot moment arm (HMA) and talar tilt angle (TTA) were calculated in the coronal view. Semiautomatic 3D measurements were performed using Disior® software. Intra-rater reliabilities were analyzed using the intraclass correlation coefficient (ICC). Agreement between methods was tested with Bland-Altman plots. Each measurement was assessed using the Wilcoxon signed-rank test. Alpha risk was set to 5% (α=0.05). P-values of ≤0.05 were considered significant. Results: ICC-measured reliabilities ranged from moderate to almost perfect for manual and semiautomatic WBCT measurements in the preoperative and postoperative groups for HMA and LTS. There was high correlation between parameters calculated from manual and semiautomatic measurements, and strong agreement between the readers and software in both groups. Conclusions: Manual (M) and semiautomatic (SA) 3D measurements expressed excellent agreement for pre- and postoperative groups, indicating a high correlation between the parameters calculated and strong agreement between the readers and the software in both groups. Level of Evidence III; Therapeutic Studies; Comparative Retrospective Study.

Duke Scholars

Published In

Journal of the Foot & Ankle

DOI

EISSN

2675-2980

Publication Date

April 30, 2022

Volume

16

Issue

1

Start / End Page

72 / 78

Publisher

Associacao Brasileira de Medicina e Cirurgia do Tornozelo e Pe (ABTPe)
 

Citation

APA
Chicago
ICMJE
MLA
NLM
Mallavarapu, V., Jasper, R., Jones, M., VandeLune, C., Alencar Mendes de Carvalho, K., Chun Kim, K., … De César Netto, C. (2022). Agreement between semiautomatic and manual measurement of selected parameters on weight-bearing computed tomography images in total ankle replacement: a retrospective study. Journal of the Foot & Ankle, 16(1), 72–78. https://doi.org/10.30795/jfootankle.2022.v16.1631
Mallavarapu, Vineel, Ryan Jasper, Matthew Jones, Christian VandeLune, Kepler Alencar Mendes de Carvalho, Ki Chun Kim, Nacime Salomão Barbachan Mansur, Kevin Dibbern, and César De César Netto. “Agreement between semiautomatic and manual measurement of selected parameters on weight-bearing computed tomography images in total ankle replacement: a retrospective study.” Journal of the Foot & Ankle 16, no. 1 (April 30, 2022): 72–78. https://doi.org/10.30795/jfootankle.2022.v16.1631.
Mallavarapu V, Jasper R, Jones M, VandeLune C, Alencar Mendes de Carvalho K, Chun Kim K, et al. Agreement between semiautomatic and manual measurement of selected parameters on weight-bearing computed tomography images in total ankle replacement: a retrospective study. Journal of the Foot & Ankle. 2022 Apr 30;16(1):72–8.
Mallavarapu, Vineel, et al. “Agreement between semiautomatic and manual measurement of selected parameters on weight-bearing computed tomography images in total ankle replacement: a retrospective study.” Journal of the Foot & Ankle, vol. 16, no. 1, Associacao Brasileira de Medicina e Cirurgia do Tornozelo e Pe (ABTPe), Apr. 2022, pp. 72–78. Crossref, doi:10.30795/jfootankle.2022.v16.1631.
Mallavarapu V, Jasper R, Jones M, VandeLune C, Alencar Mendes de Carvalho K, Chun Kim K, Barbachan Mansur NS, Dibbern K, De César Netto C. Agreement between semiautomatic and manual measurement of selected parameters on weight-bearing computed tomography images in total ankle replacement: a retrospective study. Journal of the Foot & Ankle. Associacao Brasileira de Medicina e Cirurgia do Tornozelo e Pe (ABTPe); 2022 Apr 30;16(1):72–78.

Published In

Journal of the Foot & Ankle

DOI

EISSN

2675-2980

Publication Date

April 30, 2022

Volume

16

Issue

1

Start / End Page

72 / 78

Publisher

Associacao Brasileira de Medicina e Cirurgia do Tornozelo e Pe (ABTPe)