In the first ever survey of patient doses in Madagascar, image quality and patient doses were evaluated in 3 rooms of 2 hospitals in Madagascar as part of an International Atomic energy Agency (IAEA) project (RAF/9/033) using protocols and instructions by IAEA experts. Corrective actions were taken mainly in terms of field size and exposure parameters adjustment and data were recollected. Image quality improved in all 3 rooms (increase: 2-35%). Dose reductions in the range of 1 to 66% in terms of ESAK were found in different examinations investigated. The max reduction was found in chest examination. The comparison with IAEA guidance levels (GL) showed that patient doses (ESAK values) are lower than international values except for chest exam in one of the rooms of the hospital. Actions are being taken to extend measurements to a national level in the near future. © 2009 Springer-Verlag.

Duke Scholars

Published In

Ifmbe Proceedings

DOI

ISSN

1680-0737

Publication Date

January 1, 2009

Volume

25

Issue

3

Start / End Page

554 / 556
 

Citation

APA
Chicago
ICMJE
MLA
NLM
Ramanandraibe, M. J., Andriambololona, R., Rakotoson, E., Tsapaki, V., Gfinter, H., & Rehani, M. (2009). Survey of image quality and patient dose in simple radiographic examinations in Madagascar: Initial results. In Ifmbe Proceedings (Vol. 25, pp. 554–556). https://doi.org/10.1007/978-3-642-03902-7_158
Ramanandraibe, M. J., R. Andriambololona, E. Rakotoson, V. Tsapaki, H. Gfinter, and M. Rehani. “Survey of image quality and patient dose in simple radiographic examinations in Madagascar: Initial results.” In Ifmbe Proceedings, 25:554–56, 2009. https://doi.org/10.1007/978-3-642-03902-7_158.
Ramanandraibe MJ, Andriambololona R, Rakotoson E, Tsapaki V, Gfinter H, Rehani M. Survey of image quality and patient dose in simple radiographic examinations in Madagascar: Initial results. In: Ifmbe Proceedings. 2009. p. 554–6.
Ramanandraibe, M. J., et al. “Survey of image quality and patient dose in simple radiographic examinations in Madagascar: Initial results.” Ifmbe Proceedings, vol. 25, no. 3, 2009, pp. 554–56. Scopus, doi:10.1007/978-3-642-03902-7_158.
Ramanandraibe MJ, Andriambololona R, Rakotoson E, Tsapaki V, Gfinter H, Rehani M. Survey of image quality and patient dose in simple radiographic examinations in Madagascar: Initial results. Ifmbe Proceedings. 2009. p. 554–556.

Published In

Ifmbe Proceedings

DOI

ISSN

1680-0737

Publication Date

January 1, 2009

Volume

25

Issue

3

Start / End Page

554 / 556