The cylindrical triple probe method is an attractive technique for measuring electron temperatures (Te) and electron number densities (ne) in a variety of plasmas sources. In practice, however, the cylindrical triple probe can be sensitive to sources of error that affect all Langmuir probe techniques. In particular, the presence of an ion drift velocity component that is perpendicular to the probe axis has been known to result in erroneous measurements of ne. Less obvious, however, is that ion flow perpendicular to the probe has a significant effect on the indicated T e. The purpose of this note is to make researchers aware of such an effect and to demonstrate a technique which can mitigate it. The approach taken to investigate this phenomenon was to make Te measurements in the plume of a 20 kW magnetoplasmadynamic thruster with the probe oriented at several angles with respect to the local ion flow.

Duke Scholars

Published In

Review of Scientific Instruments

DOI

ISSN

0034-6748

Publication Date

December 1, 1994

Volume

65

Issue

3

Start / End Page

678 / 681

Related Subject Headings

  • Applied Physics
  • 51 Physical sciences
  • 40 Engineering
  • 34 Chemical sciences
  • 09 Engineering
  • 03 Chemical Sciences
  • 02 Physical Sciences
 

Citation

APA
Chicago
ICMJE
MLA
NLM
Tilley, D. L., Gallimore, A. D., Kelly, A. J., & Jahn, R. G. (1994). The adverse effect of perpendicular ion drift flow on cylindrical triple probe electron temperature measurements. Review of Scientific Instruments, 65(3), 678–681. https://doi.org/10.1063/1.1145138
Tilley, D. L., A. D. Gallimore, A. J. Kelly, and R. G. Jahn. “The adverse effect of perpendicular ion drift flow on cylindrical triple probe electron temperature measurements.” Review of Scientific Instruments 65, no. 3 (December 1, 1994): 678–81. https://doi.org/10.1063/1.1145138.
Tilley DL, Gallimore AD, Kelly AJ, Jahn RG. The adverse effect of perpendicular ion drift flow on cylindrical triple probe electron temperature measurements. Review of Scientific Instruments. 1994 Dec 1;65(3):678–81.
Tilley, D. L., et al. “The adverse effect of perpendicular ion drift flow on cylindrical triple probe electron temperature measurements.” Review of Scientific Instruments, vol. 65, no. 3, Dec. 1994, pp. 678–81. Scopus, doi:10.1063/1.1145138.
Tilley DL, Gallimore AD, Kelly AJ, Jahn RG. The adverse effect of perpendicular ion drift flow on cylindrical triple probe electron temperature measurements. Review of Scientific Instruments. 1994 Dec 1;65(3):678–681.

Published In

Review of Scientific Instruments

DOI

ISSN

0034-6748

Publication Date

December 1, 1994

Volume

65

Issue

3

Start / End Page

678 / 681

Related Subject Headings

  • Applied Physics
  • 51 Physical sciences
  • 40 Engineering
  • 34 Chemical sciences
  • 09 Engineering
  • 03 Chemical Sciences
  • 02 Physical Sciences