Skip to main content

Gridded retarding pressure sensor for ion and neutral particle analysis in flowing plasmas

Publication ,  Journal Article
King, LB; Gallimore, AD
Published in: Review of Scientific Instruments
January 1, 1997

Although classical electrostatic plasma probes can provide detailed information regarding electrons and ions, these devices rely on charge-carrying particles both for energy filtering and for detection. Neutral particles are transparent to such diagnostics. In light of this a new probe design was developed to provide a measurement of the neutral particle flux component of a flowing plasma. The simple design adopted for this probe utilizes a set of electrostatic retarding grids to remove the charged particles from the flow. The neutral particles are sensed within the tube of an off-the-shelf hot cathode ionization gauge. Additionally, by varying the potential on the retarding grids, this same probe configuration can be used to measure the ion energy distribution. Preliminary data from this probe were taken in the exhaust plume of a Hall-current accelerator designed for space propulsion. This probe was found to be a very simple, accurate diagnostic tool for such use. By using this probe in combination with interrelated diagnostics the spatial distribution of energetic charge exchange neutrals was quantified in the plume of an SPT-100 thruster. © 1997 American Institute of Physics.

Duke Scholars

Published In

Review of Scientific Instruments

DOI

ISSN

0034-6748

Publication Date

January 1, 1997

Volume

68

Issue

2

Start / End Page

1183 / 1194

Related Subject Headings

  • Applied Physics
  • 51 Physical sciences
  • 40 Engineering
  • 34 Chemical sciences
  • 09 Engineering
  • 03 Chemical Sciences
  • 02 Physical Sciences
 

Citation

APA
Chicago
ICMJE
MLA
NLM
King, L. B., & Gallimore, A. D. (1997). Gridded retarding pressure sensor for ion and neutral particle analysis in flowing plasmas. Review of Scientific Instruments, 68(2), 1183–1194. https://doi.org/10.1063/1.1147881
King, L. B., and A. D. Gallimore. “Gridded retarding pressure sensor for ion and neutral particle analysis in flowing plasmas.” Review of Scientific Instruments 68, no. 2 (January 1, 1997): 1183–94. https://doi.org/10.1063/1.1147881.
King LB, Gallimore AD. Gridded retarding pressure sensor for ion and neutral particle analysis in flowing plasmas. Review of Scientific Instruments. 1997 Jan 1;68(2):1183–94.
King, L. B., and A. D. Gallimore. “Gridded retarding pressure sensor for ion and neutral particle analysis in flowing plasmas.” Review of Scientific Instruments, vol. 68, no. 2, Jan. 1997, pp. 1183–94. Scopus, doi:10.1063/1.1147881.
King LB, Gallimore AD. Gridded retarding pressure sensor for ion and neutral particle analysis in flowing plasmas. Review of Scientific Instruments. 1997 Jan 1;68(2):1183–1194.

Published In

Review of Scientific Instruments

DOI

ISSN

0034-6748

Publication Date

January 1, 1997

Volume

68

Issue

2

Start / End Page

1183 / 1194

Related Subject Headings

  • Applied Physics
  • 51 Physical sciences
  • 40 Engineering
  • 34 Chemical sciences
  • 09 Engineering
  • 03 Chemical Sciences
  • 02 Physical Sciences