To establish normal values of the optic nerve sheath diameter (ONSD) in children and adolescents for transbulbar sonography and magnetic resonance imaging.In 99 children and adolescents (age: 5.6 - 18.6 years, mean: 12 years) without neurologic or ophthalmologic disease, measurements of the ONSD with transbulbar sonography were performed. For comparison 59 children and adolescents (age: 5.1 - 17.4 years, mean 12.3 years) with a normal MR examination of the brain had measurements of the ONSD on a T2-weighted thin section sequence of the orbit. Besides establishing modality-related normal values, age dependency, accuracy and reproducibility of measurements were assessed.Overall the mean ONSD was 5.75 ± 0.52 mm for transbulbar sonography and 5.69 ± 0.31 mm for MRI. There was no statistical significance between the 95 % percentiles and age for both transbulbar sonography (p = 0.332) and MRI (p = 0.336). As a parameter for the reproducibility of measurements, the repeatability coefficient (RC) was between 0.34 mm and 0.46 mm. The concordance correlation coefficient (CCC) values revealed a high agreement between readers both for transbulbar sonography (0.868) and MRI (0.796).Normal values for ONSD in children and adolescents found in this study are significantly higher than assumed. The values found for transbulbar sonography are confirmed by comparable results for MR measurements. A precise sonographic measurement technique and the consideration of normal values found hereby are essential for correct interpretation of ONSD measurements in children and adolescents.

Duke Scholars

Published In

Ultraschall in der Medizin (Stuttgart, Germany : 1980)

DOI

EISSN

1438-8782

ISSN

0172-4614

Publication Date

February 2015

Volume

36

Issue

1

Start / End Page

54 / 58

Related Subject Headings

  • Ultrasonography
  • Sensitivity and Specificity
  • Reference Values
  • Orbit
  • Optic Nerve
  • Nuclear Medicine & Medical Imaging
  • Myelin Sheath
  • Male
  • Magnetic Resonance Imaging
  • Humans
 

Citation

APA
Chicago
ICMJE
MLA
NLM
Steinborn, M., Friedmann, M., Hahn, H., Hapfelmeier, A., Macdonald, E., Warncke, K., & Saleh, A. (2015). Normal values for transbulbar sonography and magnetic resonance imaging of the optic nerve sheath diameter (ONSD) in children and adolescents. Ultraschall in Der Medizin (Stuttgart, Germany : 1980), 36(1), 54–58. https://doi.org/10.1055/s-0034-1385012
Steinborn, M., M. Friedmann, H. Hahn, A. Hapfelmeier, E. Macdonald, K. Warncke, and A. Saleh. “Normal values for transbulbar sonography and magnetic resonance imaging of the optic nerve sheath diameter (ONSD) in children and adolescents.Ultraschall in Der Medizin (Stuttgart, Germany : 1980) 36, no. 1 (February 2015): 54–58. https://doi.org/10.1055/s-0034-1385012.
Steinborn M, Friedmann M, Hahn H, Hapfelmeier A, Macdonald E, Warncke K, et al. Normal values for transbulbar sonography and magnetic resonance imaging of the optic nerve sheath diameter (ONSD) in children and adolescents. Ultraschall in der Medizin (Stuttgart, Germany : 1980). 2015 Feb;36(1):54–8.
Steinborn, M., et al. “Normal values for transbulbar sonography and magnetic resonance imaging of the optic nerve sheath diameter (ONSD) in children and adolescents.Ultraschall in Der Medizin (Stuttgart, Germany : 1980), vol. 36, no. 1, Feb. 2015, pp. 54–58. Epmc, doi:10.1055/s-0034-1385012.
Steinborn M, Friedmann M, Hahn H, Hapfelmeier A, Macdonald E, Warncke K, Saleh A. Normal values for transbulbar sonography and magnetic resonance imaging of the optic nerve sheath diameter (ONSD) in children and adolescents. Ultraschall in der Medizin (Stuttgart, Germany : 1980). 2015 Feb;36(1):54–58.
Journal cover image

Published In

Ultraschall in der Medizin (Stuttgart, Germany : 1980)

DOI

EISSN

1438-8782

ISSN

0172-4614

Publication Date

February 2015

Volume

36

Issue

1

Start / End Page

54 / 58

Related Subject Headings

  • Ultrasonography
  • Sensitivity and Specificity
  • Reference Values
  • Orbit
  • Optic Nerve
  • Nuclear Medicine & Medical Imaging
  • Myelin Sheath
  • Male
  • Magnetic Resonance Imaging
  • Humans