Skip to main content
Journal cover image

Effects of pedal frequency on estimated muscle microvascular O2 extraction.

Publication ,  Journal Article
Ferreira, LF; Lutjemeier, BJ; Townsend, DK; Barstow, TJ
Published in: Eur J Appl Physiol
March 2006

An increase in muscle contraction frequency could limit muscle blood flow QM compromising the matching of QM and muscle oxygen uptake VO2M. This study examined the effects of pedal cadence on skeletal muscle oxygenation at low, moderate and peak exercise. Nine healthy subjects [24.7+/-6.3 years (SD)] performed incremental cycling exercise at 60 and 100 rpm. Pulmonary VO2(VO2P) was measured breath-by-breath and vastus lateralis oxygenation was determined by near-infrared spectroscopy (NIRS). The deoxyhemoglobin signal ([HHb]) from NIRS was used to estimate microvascular O2 extraction (i.e., [HHb] proportional, variant VO2M/QM). The VO2P and [HHb] for low, moderate and at peak exercise were determined. The VO2P at 60 rpm (low=0.64+/-0.13, moderate=2.03+/-0.38 and peak=3.39+/-0.84 l/min) were lower (P<0.01) than at 100 rpm (1.29+/-0.23, 2.14+/-0.39 and 3.54+/-0.88 l/min, respectively). There was a progressive increase in [HHb] from low to peak exercise. However, there was no significant difference (ANOVA, P=0.94) for the 60 (in microM, low=24.0+/-9.5, moderate=30.5+/-13.8 and peak=36.7+/-16.5) and 100 contractions/min (in microM, low=25.7+/-11.6, moderate=32.1+/-14.0 and peak=35.4+/-16.5). We conclude that vastus lateralis O2 extraction was similar at 60 and 100 cpm, suggesting that the VO2M/QM in the microcirculation was not altered and, presumably, no impairment of QM occurred with the increase in pedal frequency.

Duke Scholars

Published In

Eur J Appl Physiol

DOI

ISSN

1439-6319

Publication Date

March 2006

Volume

96

Issue

5

Start / End Page

558 / 563

Location

Germany

Related Subject Headings

  • Sport Sciences
  • Spectroscopy, Near-Infrared
  • Regional Blood Flow
  • Physical Exertion
  • Oxygen Consumption
  • Oxygen
  • Muscle, Skeletal
  • Muscle Contraction
  • Microcirculation
  • Male
 

Citation

APA
Chicago
ICMJE
MLA
NLM
Ferreira, L. F., Lutjemeier, B. J., Townsend, D. K., & Barstow, T. J. (2006). Effects of pedal frequency on estimated muscle microvascular O2 extraction. Eur J Appl Physiol, 96(5), 558–563. https://doi.org/10.1007/s00421-005-0107-3
Ferreira, Leonardo F., Barbara J. Lutjemeier, Dana K. Townsend, and Thomas J. Barstow. “Effects of pedal frequency on estimated muscle microvascular O2 extraction.Eur J Appl Physiol 96, no. 5 (March 2006): 558–63. https://doi.org/10.1007/s00421-005-0107-3.
Ferreira LF, Lutjemeier BJ, Townsend DK, Barstow TJ. Effects of pedal frequency on estimated muscle microvascular O2 extraction. Eur J Appl Physiol. 2006 Mar;96(5):558–63.
Ferreira, Leonardo F., et al. “Effects of pedal frequency on estimated muscle microvascular O2 extraction.Eur J Appl Physiol, vol. 96, no. 5, Mar. 2006, pp. 558–63. Pubmed, doi:10.1007/s00421-005-0107-3.
Ferreira LF, Lutjemeier BJ, Townsend DK, Barstow TJ. Effects of pedal frequency on estimated muscle microvascular O2 extraction. Eur J Appl Physiol. 2006 Mar;96(5):558–563.
Journal cover image

Published In

Eur J Appl Physiol

DOI

ISSN

1439-6319

Publication Date

March 2006

Volume

96

Issue

5

Start / End Page

558 / 563

Location

Germany

Related Subject Headings

  • Sport Sciences
  • Spectroscopy, Near-Infrared
  • Regional Blood Flow
  • Physical Exertion
  • Oxygen Consumption
  • Oxygen
  • Muscle, Skeletal
  • Muscle Contraction
  • Microcirculation
  • Male