Skip to main content
Journal cover image

Best Practice for MRI Diagnostic Accuracy Research With Lessons and Examples from the LI-RADS Individual Participant Data Group.

Publication ,  Journal Article
van der Pol, CB; Costa, AF; Lam, E; Dawit, H; Bashir, MR; McInnes, MDF
Published in: J Magn Reson Imaging
July 2024

Medical imaging diagnostic test accuracy research is strengthened by adhering to best practices for study design, data collection, data documentation, and study reporting. In this review, key elements of such research are discussed, and specific recommendations provided for optimizing diagnostic accuracy study execution to improve uniformity, minimize common sources of bias and avoid potential pitfalls. Examples are provided regarding study methodology and data collection practices based on insights gained by the liver imaging reporting and data system (LI-RADS) individual participant data group, who have evaluated raw data from numerous MRI diagnostic accuracy studies for risk of bias and data integrity. The goal of this review is to outline strategies for investigators to improve research practices, and to help reviewers and readers better contextualize a study's findings while understanding its limitations. LEVEL OF EVIDENCE: 5 TECHNICAL EFFICACY: Stage 3.

Duke Scholars

Published In

J Magn Reson Imaging

DOI

EISSN

1522-2586

Publication Date

July 2024

Volume

60

Issue

1

Start / End Page

21 / 28

Location

United States

Related Subject Headings

  • Research Design
  • Reproducibility of Results
  • Radiology Information Systems
  • Nuclear Medicine & Medical Imaging
  • Magnetic Resonance Imaging
  • Liver
  • Humans
  • 3202 Clinical sciences
  • 11 Medical and Health Sciences
  • 09 Engineering
 

Citation

APA
Chicago
ICMJE
MLA
NLM
van der Pol, C. B., Costa, A. F., Lam, E., Dawit, H., Bashir, M. R., & McInnes, M. D. F. (2024). Best Practice for MRI Diagnostic Accuracy Research With Lessons and Examples from the LI-RADS Individual Participant Data Group. J Magn Reson Imaging, 60(1), 21–28. https://doi.org/10.1002/jmri.29049
Pol, Christian B. van der, Andreu F. Costa, Eric Lam, Haben Dawit, Mustafa R. Bashir, and Matthew D. F. McInnes. “Best Practice for MRI Diagnostic Accuracy Research With Lessons and Examples from the LI-RADS Individual Participant Data Group.J Magn Reson Imaging 60, no. 1 (July 2024): 21–28. https://doi.org/10.1002/jmri.29049.
van der Pol CB, Costa AF, Lam E, Dawit H, Bashir MR, McInnes MDF. Best Practice for MRI Diagnostic Accuracy Research With Lessons and Examples from the LI-RADS Individual Participant Data Group. J Magn Reson Imaging. 2024 Jul;60(1):21–8.
van der Pol, Christian B., et al. “Best Practice for MRI Diagnostic Accuracy Research With Lessons and Examples from the LI-RADS Individual Participant Data Group.J Magn Reson Imaging, vol. 60, no. 1, July 2024, pp. 21–28. Pubmed, doi:10.1002/jmri.29049.
van der Pol CB, Costa AF, Lam E, Dawit H, Bashir MR, McInnes MDF. Best Practice for MRI Diagnostic Accuracy Research With Lessons and Examples from the LI-RADS Individual Participant Data Group. J Magn Reson Imaging. 2024 Jul;60(1):21–28.
Journal cover image

Published In

J Magn Reson Imaging

DOI

EISSN

1522-2586

Publication Date

July 2024

Volume

60

Issue

1

Start / End Page

21 / 28

Location

United States

Related Subject Headings

  • Research Design
  • Reproducibility of Results
  • Radiology Information Systems
  • Nuclear Medicine & Medical Imaging
  • Magnetic Resonance Imaging
  • Liver
  • Humans
  • 3202 Clinical sciences
  • 11 Medical and Health Sciences
  • 09 Engineering