Skip to main content

Quantitative texture analysis: Robustness of radiomics across two digital mammography manufacturers' systems

Publication ,  Journal Article
Mendel, KR; Li, H; Lan, L; Cahill, CM; Rael, V; Abe, H; Giger, ML
Published in: Journal of Medical Imaging
January 1, 2018

The robustness of radiomic texture analysis across different manufacturers of mammography imaging systems is investigated. We quantified feature robustness across mammography manufacturers using a dataset of 111 women who underwent consecutive screening mammography on both general electric and Hologic systems. In each mammogram, a square region of interest (ROI) directly behind the nipple was manually selected. Radiomic features describing parenchymal patterns were automatically extracted on each ROI. Feature comparisons were conducted between manufacturers (and breast densities) using newly developed robustness metrics descriptive of correlation, equivalence, and variability. By examining the distribution of these metric values, we propose the following selection criteria to guide feature evaluation in this dataset: (1) 0.8

Duke Scholars

Altmetric Attention Stats
Dimensions Citation Stats

Published In

Journal of Medical Imaging

DOI

EISSN

2329-4310

ISSN

2329-4302

Publication Date

January 1, 2018

Volume

5

Issue

1

Related Subject Headings

  • 4003 Biomedical engineering
  • 3202 Clinical sciences
 

Citation

APA
Chicago
ICMJE
MLA
NLM
Mendel, K. R., Li, H., Lan, L., Cahill, C. M., Rael, V., Abe, H., & Giger, M. L. (2018). Quantitative texture analysis: Robustness of radiomics across two digital mammography manufacturers' systems. Journal of Medical Imaging, 5(1). https://doi.org/10.1117/1.JMI.5.1.011002
Mendel, K. R., H. Li, L. Lan, C. M. Cahill, V. Rael, H. Abe, and M. L. Giger. “Quantitative texture analysis: Robustness of radiomics across two digital mammography manufacturers' systems.” Journal of Medical Imaging 5, no. 1 (January 1, 2018). https://doi.org/10.1117/1.JMI.5.1.011002.
Mendel KR, Li H, Lan L, Cahill CM, Rael V, Abe H, et al. Quantitative texture analysis: Robustness of radiomics across two digital mammography manufacturers' systems. Journal of Medical Imaging. 2018 Jan 1;5(1).
Mendel, K. R., et al. “Quantitative texture analysis: Robustness of radiomics across two digital mammography manufacturers' systems.” Journal of Medical Imaging, vol. 5, no. 1, Jan. 2018. Scopus, doi:10.1117/1.JMI.5.1.011002.
Mendel KR, Li H, Lan L, Cahill CM, Rael V, Abe H, Giger ML. Quantitative texture analysis: Robustness of radiomics across two digital mammography manufacturers' systems. Journal of Medical Imaging. 2018 Jan 1;5(1).

Published In

Journal of Medical Imaging

DOI

EISSN

2329-4310

ISSN

2329-4302

Publication Date

January 1, 2018

Volume

5

Issue

1

Related Subject Headings

  • 4003 Biomedical engineering
  • 3202 Clinical sciences