Skip to main content

Automatic selection of region of interest for radiographic texture analysis

Publication ,  Conference
Lan, L; Giger, ML; Wilkie, JR; Vokes, TJ; Chen, W; Li, H; Lyons, T; Chinander, MR; Pham, A
Published in: Progress in Biomedical Optics and Imaging - Proceedings of SPIE
October 18, 2007

We have been developing radiographic texture analysis (RTA) for assessing osteoporosis and the related risk of fracture. Currently, analyses are performed on heel images obtained from a digital imaging device, the GE/Lunar PIXI, that yields both the bone mineral density (BMD) and digital images (0.2-mm pixels; 12-bit quantization). RTA is performed on the image data in a region-of-interest (ROI) placed just below the talus in order to include the trabecular structure in the analysis. We have found that variations occur from manually selecting this ROI for RTA. To reduce the variations, we present an automatic method involving an optimized Canny edge detection technique and parameterized bone segmentation, to define bone edges for the placement of an ROI within the predominantly calcaneus portion of the radiographic heel image. The technique was developed using 1158 heel images and then tested on an independent set of 176 heel images. Results from a subjective analysis noted that 87.5% of ROI placements were rated as "good". In addition, an objective overlap measure showed that 98.3% of images had successful ROI placements as compared to placement by an experienced observer at an overlap threshold of 0.4. In conclusion, our proposed method for automatic ROI selection on radiographic heel images yields promising results and the method has the potential to reduce intra- and inter-observer variations in selecting ROIs for radiographic texture analysis.

Duke Scholars

Published In

Progress in Biomedical Optics and Imaging - Proceedings of SPIE

DOI

ISSN

1605-7422

Publication Date

October 18, 2007

Volume

6514

Issue

PART 2
 

Citation

APA
Chicago
ICMJE
MLA
NLM
Lan, L., Giger, M. L., Wilkie, J. R., Vokes, T. J., Chen, W., Li, H., … Pham, A. (2007). Automatic selection of region of interest for radiographic texture analysis. In Progress in Biomedical Optics and Imaging - Proceedings of SPIE (Vol. 6514). https://doi.org/10.1117/12.711531
Lan, L., M. L. Giger, J. R. Wilkie, T. J. Vokes, W. Chen, H. Li, T. Lyons, M. R. Chinander, and A. Pham. “Automatic selection of region of interest for radiographic texture analysis.” In Progress in Biomedical Optics and Imaging - Proceedings of SPIE, Vol. 6514, 2007. https://doi.org/10.1117/12.711531.
Lan L, Giger ML, Wilkie JR, Vokes TJ, Chen W, Li H, et al. Automatic selection of region of interest for radiographic texture analysis. In: Progress in Biomedical Optics and Imaging - Proceedings of SPIE. 2007.
Lan, L., et al. “Automatic selection of region of interest for radiographic texture analysis.” Progress in Biomedical Optics and Imaging - Proceedings of SPIE, vol. 6514, no. PART 2, 2007. Scopus, doi:10.1117/12.711531.
Lan L, Giger ML, Wilkie JR, Vokes TJ, Chen W, Li H, Lyons T, Chinander MR, Pham A. Automatic selection of region of interest for radiographic texture analysis. Progress in Biomedical Optics and Imaging - Proceedings of SPIE. 2007.

Published In

Progress in Biomedical Optics and Imaging - Proceedings of SPIE

DOI

ISSN

1605-7422

Publication Date

October 18, 2007

Volume

6514

Issue

PART 2