Skip to main content
Journal cover image

Accurate calibration of test mass displacement in the LIGO interferometers

Publication ,  Journal Article
Goetz, E; Savage, RL; Garofoli, J; Gonzalez, G; Hirose, E; Kalmus, P; Kawabe, K; Kissel, J; Landry, M; O'Reilly, B; Siemens, X; Stuver, A; Sung, M
Published in: Classical and Quantum Gravity
April 14, 2010

We describe three fundamentally different methods we have applied to calibrate the test mass displacement actuators to search for systematic errors in the calibration of the LIGO gravitational-wave detectors. The actuation frequencies tested range from 90 Hz to 1 kHz and the actuation amplitudes range from 10-6 m to 10-18 m. For each of the four test mass actuators measured, the weighted mean coefficient over all frequencies for each technique deviates from the average actuation coefficient for all three techniques by less than 4%. This result indicates that systematic errors in the calibration of the responses of the LIGO detectors to differential length variations are within the stated uncertainties. © 2010 IOP Publishing Ltd.

Duke Scholars

Published In

Classical and Quantum Gravity

DOI

EISSN

1361-6382

ISSN

0264-9381

Publication Date

April 14, 2010

Volume

27

Issue

8

Related Subject Headings

  • Nuclear & Particles Physics
  • 51 Physical sciences
  • 49 Mathematical sciences
  • 02 Physical Sciences
  • 01 Mathematical Sciences
 

Citation

APA
Chicago
ICMJE
MLA
NLM
Goetz, E., Savage, R. L., Garofoli, J., Gonzalez, G., Hirose, E., Kalmus, P., … Sung, M. (2010). Accurate calibration of test mass displacement in the LIGO interferometers. Classical and Quantum Gravity, 27(8). https://doi.org/10.1088/0264-9381/27/8/084024
Goetz, E., R. L. Savage, J. Garofoli, G. Gonzalez, E. Hirose, P. Kalmus, K. Kawabe, et al. “Accurate calibration of test mass displacement in the LIGO interferometers.” Classical and Quantum Gravity 27, no. 8 (April 14, 2010). https://doi.org/10.1088/0264-9381/27/8/084024.
Goetz E, Savage RL, Garofoli J, Gonzalez G, Hirose E, Kalmus P, et al. Accurate calibration of test mass displacement in the LIGO interferometers. Classical and Quantum Gravity. 2010 Apr 14;27(8).
Goetz, E., et al. “Accurate calibration of test mass displacement in the LIGO interferometers.” Classical and Quantum Gravity, vol. 27, no. 8, Apr. 2010. Scopus, doi:10.1088/0264-9381/27/8/084024.
Goetz E, Savage RL, Garofoli J, Gonzalez G, Hirose E, Kalmus P, Kawabe K, Kissel J, Landry M, O’Reilly B, Siemens X, Stuver A, Sung M. Accurate calibration of test mass displacement in the LIGO interferometers. Classical and Quantum Gravity. 2010 Apr 14;27(8).
Journal cover image

Published In

Classical and Quantum Gravity

DOI

EISSN

1361-6382

ISSN

0264-9381

Publication Date

April 14, 2010

Volume

27

Issue

8

Related Subject Headings

  • Nuclear & Particles Physics
  • 51 Physical sciences
  • 49 Mathematical sciences
  • 02 Physical Sciences
  • 01 Mathematical Sciences