Skip to main content

Influence of Body Mass Index in Donor-Recipient Size Mismatch in Pediatric Heart Transplantation.

Publication ,  Journal Article
Lowrey, LK; Trivedi, J; Ramakrishnan, K; Sinha, P; Deshpande, SR
Published in: World J Pediatr Congenit Heart Surg
January 2023

BACKGROUND: Body weight is the traditional metric for matching donor and recipient size for pediatric heart transplantation (pHT). We hypothesized that mismatch in body mass index (BMI) or body surface area (BSA) rather than weight is better associated with outcomes of transplantation and therefore should be used for donor-recipient size matching. METHODS: Analysis of the United Network for Organ Sharing database limited to pHT recipients was performed. Donor and recipient mismatch groups were created for weight, BMI, and BSA ratios. Differences in recipient characteristics between each cohort and the impact of mismatch on outcomes were statistically analyzed. RESULTS: A total of 4,465 patients were included in the analysis of which 43% had congenital heart disease (CHD). There were significant differences in patient characteristics by matching, independent of the matching parameter. Multivariable regression analysis showed that a low donor-recipient BMI ratio (compared to normal) (CHD OR 1.70; non-CHD 2.78) was a predictor of one-year mortality (all P < .001) in both CHD and non-CHD cohorts. Low BMI ratio was also associated with worse long-term survival in non-CHD groups, but not in the CHD cohort. Weight and BSA ratio did not predict one year or long-term survival. CONCLUSION: The use of low BMI donors compared to recipient may predict poor early and long-term survival and therefore should be avoided in pHT. The use of BMI matching may improve donor-recipient matching in pHT.

Duke Scholars

Published In

World J Pediatr Congenit Heart Surg

DOI

EISSN

2150-136X

Publication Date

January 2023

Volume

14

Issue

1

Start / End Page

31 / 39

Location

United States

Related Subject Headings

  • Tissue Donors
  • Humans
  • Heart Transplantation
  • Databases, Factual
  • Child
  • Body Mass Index
  • 3213 Paediatrics
  • 3202 Clinical sciences
  • 3201 Cardiovascular medicine and haematology
  • 1114 Paediatrics and Reproductive Medicine
 

Citation

APA
Chicago
ICMJE
MLA
NLM
Lowrey, L. K., Trivedi, J., Ramakrishnan, K., Sinha, P., & Deshpande, S. R. (2023). Influence of Body Mass Index in Donor-Recipient Size Mismatch in Pediatric Heart Transplantation. World J Pediatr Congenit Heart Surg, 14(1), 31–39. https://doi.org/10.1177/21501351221127284
Lowrey, Laura K., Jaimin Trivedi, Karthik Ramakrishnan, Pranava Sinha, and Shriprasad R. Deshpande. “Influence of Body Mass Index in Donor-Recipient Size Mismatch in Pediatric Heart Transplantation.World J Pediatr Congenit Heart Surg 14, no. 1 (January 2023): 31–39. https://doi.org/10.1177/21501351221127284.
Lowrey LK, Trivedi J, Ramakrishnan K, Sinha P, Deshpande SR. Influence of Body Mass Index in Donor-Recipient Size Mismatch in Pediatric Heart Transplantation. World J Pediatr Congenit Heart Surg. 2023 Jan;14(1):31–9.
Lowrey, Laura K., et al. “Influence of Body Mass Index in Donor-Recipient Size Mismatch in Pediatric Heart Transplantation.World J Pediatr Congenit Heart Surg, vol. 14, no. 1, Jan. 2023, pp. 31–39. Pubmed, doi:10.1177/21501351221127284.
Lowrey LK, Trivedi J, Ramakrishnan K, Sinha P, Deshpande SR. Influence of Body Mass Index in Donor-Recipient Size Mismatch in Pediatric Heart Transplantation. World J Pediatr Congenit Heart Surg. 2023 Jan;14(1):31–39.

Published In

World J Pediatr Congenit Heart Surg

DOI

EISSN

2150-136X

Publication Date

January 2023

Volume

14

Issue

1

Start / End Page

31 / 39

Location

United States

Related Subject Headings

  • Tissue Donors
  • Humans
  • Heart Transplantation
  • Databases, Factual
  • Child
  • Body Mass Index
  • 3213 Paediatrics
  • 3202 Clinical sciences
  • 3201 Cardiovascular medicine and haematology
  • 1114 Paediatrics and Reproductive Medicine