Skip to main content
Journal cover image

Modification of a Transvalvular Microaxial Flow Pump for Instantaneous Determination of Native Cardiac Output and Volume.

Publication ,  Journal Article
Aslam, MI; Gruslova, AB; Almomani, A; Nolen, D; Elliott, JJ; Jani, VP; Kottam, A; Porterfield, J; Heighten, C; Anderson, AS; Valvano, JW; Feldman, MD
Published in: Journal of cardiac failure
October 2023

The current Impella cardiopulmonary (CP) pump, used for mechanical circulatory support in patients with cardiogenic shock (CS), cannot assess native cardiac output (CO) and left ventricular (LV) volumes. These data are valuable in facilitating device management and weaning. Admittance technology allows for accurate assessment of cardiac chamber volumes.This study tested the ability to engineer admittance electrodes onto an existing Impella CP pump to assess total and native CO as well as LV chamber volumes in an instantaneous manner.Impella CP pumps were fitted with 4 admittance electrodes and were placed in the LVs of adult swine (n = 9) that were subjected to 3 different hemodynamic conditions, including Impella CP speed adjustments, administration of escalating doses of dobutamine and microsphere injections into the left main artery to result in cardiac injury. CO, according to admittance electrodes, was calculated from LV volumes and heart rate. In addition, CO was calculated in each instance via thermodilution, continuous CO measurement, the Fick principle, and aortic velocity-time integral by means of echocardiography.Modified Impella CP pumps were placed in swine LVs successfully. CO, as determined by admittance electrodes, was similar by trend to other methods of CO assessment. It was corrected for pump speed to calculate native CO, and calculated LV chamber volumes trended as expected in each experimental protocol.We report, for the first time, that an Impella CP pump can be fitted with admittance electrodes and used to determine total and native CO in various hemodynamic situations.Transvalvular mechanical circulatory support devices such as the Impella CP do not have the ability to provide real-time information on native cardiac output (CO) and left ventricular (LV) volumes. This information is critical in device management and in weaning in patients with cardiogenic shock. We demonstrate, for the first time, that Impella CP pumps coupled with admittance electrodes are able to determine native CO and LV chamber volumes in multiple hemodynamic situations such as Impella pump speed adjustments, escalating dobutamine administration and cardiac injury from microsphere injection.

Published In

Journal of cardiac failure

DOI

EISSN

1532-8414

ISSN

1071-9164

Publication Date

October 2023

Volume

29

Issue

10

Start / End Page

1369 / 1379

Related Subject Headings

  • Cardiovascular System & Hematology
  • 3202 Clinical sciences
  • 3201 Cardiovascular medicine and haematology
  • 1110 Nursing
  • 1103 Clinical Sciences
  • 1102 Cardiorespiratory Medicine and Haematology
 

Citation

APA
Chicago
ICMJE
MLA
NLM
Aslam, M. I., Gruslova, A. B., Almomani, A., Nolen, D., Elliott, J. J., Jani, V. P., … Feldman, M. D. (2023). Modification of a Transvalvular Microaxial Flow Pump for Instantaneous Determination of Native Cardiac Output and Volume. Journal of Cardiac Failure, 29(10), 1369–1379. https://doi.org/10.1016/j.cardfail.2023.04.007
Aslam, M Imran, Aleksandra B. Gruslova, Ahmed Almomani, Drew Nolen, James J. Elliott, Vivek P. Jani, Anil Kottam, et al. “Modification of a Transvalvular Microaxial Flow Pump for Instantaneous Determination of Native Cardiac Output and Volume.Journal of Cardiac Failure 29, no. 10 (October 2023): 1369–79. https://doi.org/10.1016/j.cardfail.2023.04.007.
Aslam MI, Gruslova AB, Almomani A, Nolen D, Elliott JJ, Jani VP, et al. Modification of a Transvalvular Microaxial Flow Pump for Instantaneous Determination of Native Cardiac Output and Volume. Journal of cardiac failure. 2023 Oct;29(10):1369–79.
Aslam, M. Imran, et al. “Modification of a Transvalvular Microaxial Flow Pump for Instantaneous Determination of Native Cardiac Output and Volume.Journal of Cardiac Failure, vol. 29, no. 10, Oct. 2023, pp. 1369–79. Epmc, doi:10.1016/j.cardfail.2023.04.007.
Aslam MI, Gruslova AB, Almomani A, Nolen D, Elliott JJ, Jani VP, Kottam A, Porterfield J, Heighten C, Anderson AS, Valvano JW, Feldman MD. Modification of a Transvalvular Microaxial Flow Pump for Instantaneous Determination of Native Cardiac Output and Volume. Journal of cardiac failure. 2023 Oct;29(10):1369–1379.
Journal cover image

Published In

Journal of cardiac failure

DOI

EISSN

1532-8414

ISSN

1071-9164

Publication Date

October 2023

Volume

29

Issue

10

Start / End Page

1369 / 1379

Related Subject Headings

  • Cardiovascular System & Hematology
  • 3202 Clinical sciences
  • 3201 Cardiovascular medicine and haematology
  • 1110 Nursing
  • 1103 Clinical Sciences
  • 1102 Cardiorespiratory Medicine and Haematology