Consistency and sealing of advanced bipolar tissue sealers

Publication ,  Journal Article
Chekan, EG; Davison, MA; Singleton, DW; Mennone, JZ; Hinoul, P
Published in: Medical Devices Evidence and Research
April 20, 2015

Objectives: The aim of this study was to evaluate two commonly used advanced bipolar devices (ENSEAL® G2 Tissue Sealers and LigaSure™ Blunt Tip) for compression uniformity, vessel sealing strength, and consistency in bench-top analyses. Methods: Compression analysis was performed with a foam pad/sensor apparatus inserted between closed jaws of the instruments. Average pressures (psi) were recorded across the entire inside surface of the jaws, and over the distal one-third of jaws. To test vessel sealing strength, ex vivo pig carotid arteries were sealed and transected and left and right (sealed) halves of vessels were subjected to burst pressure testing. The maximum bursting pressures of each half of vessels were averaged to obtain single data points for analysis. The absence or presence of tissue sticking to device jaws was noted for each transected vessel. Results: Statistically higher average compression values were found for ENSEAL® instruments (curved jaw and straight jaw) compared to LigaSure™, P<0.05. Moreover, the ENSEAL® devices retained full compression at the distal end of jaws. Significantly higher and more consistent median burst pressures were noted for ENSEAL® devices relative to LigaSure™ through 52 firings of each device (P<05). LigaSure™ showed a significant reduction in median burst pressure for the final three firings (cycles 50–52) versus the first three firings (cycles 1–3), P=0.027. Tissue sticking was noted for 1.39% and 13.3% of vessels transected with ENSEAL® and LigaSure™, respectively. Conclusion: In bench-top testing, ENSEAL® G2 sealers produced more uniform compression, stronger and more consistent vessel sealing, and reduced tissue sticking relative to LigaSure™.

Duke Scholars

Published In

Medical Devices Evidence and Research

DOI

EISSN

1179-1470

Publication Date

April 20, 2015

Volume

8

Start / End Page

193 / 199

Related Subject Headings

  • 3202 Clinical sciences
  • 1103 Clinical Sciences
  • 0903 Biomedical Engineering
 

Citation

APA
Chicago
ICMJE
MLA
NLM
Chekan, E. G., Davison, M. A., Singleton, D. W., Mennone, J. Z., & Hinoul, P. (2015). Consistency and sealing of advanced bipolar tissue sealers. Medical Devices Evidence and Research, 8, 193–199. https://doi.org/10.2147/MDER.S79642
Chekan, E. G., M. A. Davison, D. W. Singleton, J. Z. Mennone, and P. Hinoul. “Consistency and sealing of advanced bipolar tissue sealers.” Medical Devices Evidence and Research 8 (April 20, 2015): 193–99. https://doi.org/10.2147/MDER.S79642.
Chekan EG, Davison MA, Singleton DW, Mennone JZ, Hinoul P. Consistency and sealing of advanced bipolar tissue sealers. Medical Devices Evidence and Research. 2015 Apr 20;8:193–9.
Chekan, E. G., et al. “Consistency and sealing of advanced bipolar tissue sealers.” Medical Devices Evidence and Research, vol. 8, Apr. 2015, pp. 193–99. Scopus, doi:10.2147/MDER.S79642.
Chekan EG, Davison MA, Singleton DW, Mennone JZ, Hinoul P. Consistency and sealing of advanced bipolar tissue sealers. Medical Devices Evidence and Research. 2015 Apr 20;8:193–199.

Published In

Medical Devices Evidence and Research

DOI

EISSN

1179-1470

Publication Date

April 20, 2015

Volume

8

Start / End Page

193 / 199

Related Subject Headings

  • 3202 Clinical sciences
  • 1103 Clinical Sciences
  • 0903 Biomedical Engineering