Skip to main content

Improvement of 2D cine image quality using 3D priors and cycle generative adversarial network for low field MRI-guided radiation therapy.

Publication ,  Journal Article
Dong, Y; Yang, F; Wen, J; Cai, J; Zeng, F; Liu, M; Li, S; Wang, J; Ford, JC; Portelance, L; Yang, Y
Published in: Med Phys
May 2024

BACKGROUND: Cine magnetic resonance (MR) images have been used for real-time MR guided radiation therapy (MRgRT). However, the onboard MR systems with low-field strength face the problem of limited image quality. PURPOSE: To improve the quality of cine MR images in MRgRT using prior image information provided by the patient planning and positioning MR images. METHODS: This study employed MR images from 18 pancreatic cancer patients who received MR-guided stereotactic body radiation therapy. Planning 3D MR images were acquired during the patient simulation, and positioning 3D MR images and 2D sagittal cine MR images were acquired before and during the beam delivery, respectively. A deep learning-based framework consisting of two cycle generative adversarial networks (CycleGAN), Denoising CycleGAN and Enhancement CycleGAN, was developed to establish the mapping between the 3D and 2D MR images. The Denoising CycleGAN was trained to first denoise the cine images using the time domain cine image series, and the Enhancement CycleGAN was trained to enhance the spatial resolution and contrast by taking advantage of the prior image information from the planning and positioning images. The denoising performance was assessed by signal-to-noise ratio (SNR), structural similarity index measure, peak SNR, blind/reference-less image spatial quality evaluator (BRISQUE), natural image quality evaluator, and perception-based image quality evaluator scores. The quality enhancement performance was assessed by the BRISQUE and physician visual scores. In addition, the target contouring was evaluated on the original and processed images. RESULTS: Significant differences were found for all evaluation metrics after Denoising CycleGAN processing. The BRISQUE and visual scores were also significantly improved after sequential Denoising and Enhancement CycleGAN processing. In target contouring evaluation, Dice similarity coefficient, centroid distance, Hausdorff distance, and average surface distance values were significantly improved on the enhanced images. The whole processing time was within 20 ms for a typical input image size of 512 × 512. CONCLUSION: Taking advantage of the prior high-quality positioning and planning MR images, the deep learning-based framework enhanced the cine MR image quality significantly, leading to improved accuracy in automatic target contouring. With the merits of both high computational efficiency and considerable image quality enhancement, the proposed method may hold important clinical implication for real-time MRgRT.

Duke Scholars

Published In

Med Phys

DOI

EISSN

2473-4209

Publication Date

May 2024

Volume

51

Issue

5

Start / End Page

3495 / 3509

Location

United States

Related Subject Headings

  • Signal-To-Noise Ratio
  • Radiotherapy, Image-Guided
  • Pancreatic Neoplasms
  • Nuclear Medicine & Medical Imaging
  • Magnetic Resonance Imaging, Cine
  • Imaging, Three-Dimensional
  • Image Processing, Computer-Assisted
  • Humans
  • Deep Learning
  • 5105 Medical and biological physics
 

Citation

APA
Chicago
ICMJE
MLA
NLM
Dong, Y., Yang, F., Wen, J., Cai, J., Zeng, F., Liu, M., … Yang, Y. (2024). Improvement of 2D cine image quality using 3D priors and cycle generative adversarial network for low field MRI-guided radiation therapy. Med Phys, 51(5), 3495–3509. https://doi.org/10.1002/mp.16860
Dong, Yuyan, Fei Yang, Jie Wen, Jing Cai, Feiyan Zeng, Mengqiu Liu, Shuang Li, et al. “Improvement of 2D cine image quality using 3D priors and cycle generative adversarial network for low field MRI-guided radiation therapy.Med Phys 51, no. 5 (May 2024): 3495–3509. https://doi.org/10.1002/mp.16860.
Dong, Yuyan, et al. “Improvement of 2D cine image quality using 3D priors and cycle generative adversarial network for low field MRI-guided radiation therapy.Med Phys, vol. 51, no. 5, May 2024, pp. 3495–509. Pubmed, doi:10.1002/mp.16860.
Dong Y, Yang F, Wen J, Cai J, Zeng F, Liu M, Li S, Wang J, Ford JC, Portelance L, Yang Y. Improvement of 2D cine image quality using 3D priors and cycle generative adversarial network for low field MRI-guided radiation therapy. Med Phys. 2024 May;51(5):3495–3509.

Published In

Med Phys

DOI

EISSN

2473-4209

Publication Date

May 2024

Volume

51

Issue

5

Start / End Page

3495 / 3509

Location

United States

Related Subject Headings

  • Signal-To-Noise Ratio
  • Radiotherapy, Image-Guided
  • Pancreatic Neoplasms
  • Nuclear Medicine & Medical Imaging
  • Magnetic Resonance Imaging, Cine
  • Imaging, Three-Dimensional
  • Image Processing, Computer-Assisted
  • Humans
  • Deep Learning
  • 5105 Medical and biological physics