Skip to main content

Accuracy of routine external ventricular drain placement following a mixed reality-guided twist-drill craniostomy.

Publication ,  Journal Article
Eom, S; Ma, TS; Vutakuri, N; Hu, T; Haskell-Mendoza, AP; Sykes, DAW; Gorlatova, M; Jackson, J
Published in: Neurosurgical focus
January 2024

The traditional freehand placement of an external ventricular drain (EVD) relies on empirical craniometric landmarks to guide the craniostomy and subsequent passage of the EVD catheter. The diameter and trajectory of the craniostomy physically limit the possible trajectories that can be achieved during the passage of the catheter. In this study, the authors implemented a mixed reality-guided craniostomy procedure to evaluate the benefit of an optimally drilled craniostomy to the accurate placement of the catheter.Optical marker-based tracking using an OptiTrack system was used to register the brain ventricular hologram and drilling guidance for craniostomy using a HoloLens 2 mixed reality headset. A patient-specific 3D-printed skull phantom embedded with intracranial camera sensors was developed to automatically calculate the EVD accuracy for evaluation. User trials consisted of one blind and one mixed reality-assisted craniostomy followed by a routine, unguided EVD catheter placement for each of two different drill bit sizes.A total of 49 participants were included in the study (mean age 23.4 years, 59.2% female). The mean distance from the catheter target improved from 18.6 ± 12.5 mm to 12.7 ± 11.3 mm (p = 0.0008) using mixed reality guidance for trials with a large drill bit and from 19.3 ± 12.7 mm to 10.1 ± 8.4 mm with a small drill bit (p < 0.0001). Accuracy using mixed reality was improved using a smaller diameter drill bit compared with a larger bit (p = 0.039). Overall, the majority of the participants were positive about the helpfulness of mixed reality guidance and the overall mixed reality experience.Appropriate indications and use cases for the application of mixed reality guidance to neurosurgical procedures remain an area of active inquiry. While prior studies have demonstrated the benefit of mixed reality-guided catheter placement using predrilled craniostomies, the authors demonstrate that real-time quantitative and visual feedback of a mixed reality-guided craniostomy procedure can independently improve procedural accuracy and represents an important tool for trainee education and eventual clinical implementation.

Duke Scholars

Published In

Neurosurgical focus

DOI

EISSN

1092-0684

ISSN

1092-0684

Publication Date

January 2024

Volume

56

Issue

1

Start / End Page

E11

Related Subject Headings

  • Young Adult
  • Neurosurgical Procedures
  • Neurology & Neurosurgery
  • Male
  • Humans
  • Female
  • Drainage
  • Cerebral Ventricles
  • Catheters
  • Augmented Reality
 

Citation

APA
Chicago
ICMJE
MLA
NLM
Eom, S., Ma, T. S., Vutakuri, N., Hu, T., Haskell-Mendoza, A. P., Sykes, D. A. W., … Jackson, J. (2024). Accuracy of routine external ventricular drain placement following a mixed reality-guided twist-drill craniostomy. Neurosurgical Focus, 56(1), E11. https://doi.org/10.3171/2023.10.focus23615
Eom, Sangjun, Tiffany S. Ma, Neha Vutakuri, Tianyi Hu, Aden P. Haskell-Mendoza, David A. W. Sykes, Maria Gorlatova, and Joshua Jackson. “Accuracy of routine external ventricular drain placement following a mixed reality-guided twist-drill craniostomy.Neurosurgical Focus 56, no. 1 (January 2024): E11. https://doi.org/10.3171/2023.10.focus23615.
Eom S, Ma TS, Vutakuri N, Hu T, Haskell-Mendoza AP, Sykes DAW, et al. Accuracy of routine external ventricular drain placement following a mixed reality-guided twist-drill craniostomy. Neurosurgical focus. 2024 Jan;56(1):E11.
Eom, Sangjun, et al. “Accuracy of routine external ventricular drain placement following a mixed reality-guided twist-drill craniostomy.Neurosurgical Focus, vol. 56, no. 1, Jan. 2024, p. E11. Epmc, doi:10.3171/2023.10.focus23615.
Eom S, Ma TS, Vutakuri N, Hu T, Haskell-Mendoza AP, Sykes DAW, Gorlatova M, Jackson J. Accuracy of routine external ventricular drain placement following a mixed reality-guided twist-drill craniostomy. Neurosurgical focus. 2024 Jan;56(1):E11.

Published In

Neurosurgical focus

DOI

EISSN

1092-0684

ISSN

1092-0684

Publication Date

January 2024

Volume

56

Issue

1

Start / End Page

E11

Related Subject Headings

  • Young Adult
  • Neurosurgical Procedures
  • Neurology & Neurosurgery
  • Male
  • Humans
  • Female
  • Drainage
  • Cerebral Ventricles
  • Catheters
  • Augmented Reality