CCAT-prime: Optical and cryogenic design of the 850 GHz module for Prime-Cam
Publication
, Conference
Huber, AI; Chapman, SC; Sinclair, AK; Spencer, LD; Austermann, JE; Choi, SK; Devina, J; Gallardo, PA; Henke, D; Huber, ZB; Keller, B; Li, Y ...
Published in: Proceedings of SPIE the International Society for Optical Engineering
January 1, 2022
Prime-Cam is a first-generation instrument for the Cerro Chajnantor Atacama Telescope-prime (CCAT-prime) Facility. The 850 GHz module for Prime-Cam will probe the highest frequency of all the instrument modules. We describe the parameter space of the 850 GHz optical system between the Fλ spacing, beam size, pixel sensitivity, and detector count. We present the optimization of an optical design for the 850 GHz instrument module for CCAT-prime. We further describe the development of the cryogenic RF chain design to accommodate 30 readout lines to read 41,400 kinetic inductance detectors (KIDs) within the cryogenic testbed.
Duke Scholars
Published In
Proceedings of SPIE the International Society for Optical Engineering
DOI
EISSN
1996-756X
ISSN
0277-786X
Publication Date
January 1, 2022
Volume
12190
Related Subject Headings
- 5102 Atomic, molecular and optical physics
- 4009 Electronics, sensors and digital hardware
- 4006 Communications engineering
Citation
APA
Chicago
ICMJE
MLA
NLM
Huber, A. I., Chapman, S. C., Sinclair, A. K., Spencer, L. D., Austermann, J. E., Choi, S. K., … Wheeler, J. D. (2022). CCAT-prime: Optical and cryogenic design of the 850 GHz module for Prime-Cam. In Proceedings of SPIE the International Society for Optical Engineering (Vol. 12190). https://doi.org/10.1117/12.2630370
Huber, A. I., S. C. Chapman, A. K. Sinclair, L. D. Spencer, J. E. Austermann, S. K. Choi, J. Devina, et al. “CCAT-prime: Optical and cryogenic design of the 850 GHz module for Prime-Cam.” In Proceedings of SPIE the International Society for Optical Engineering, Vol. 12190, 2022. https://doi.org/10.1117/12.2630370.
Huber AI, Chapman SC, Sinclair AK, Spencer LD, Austermann JE, Choi SK, et al. CCAT-prime: Optical and cryogenic design of the 850 GHz module for Prime-Cam. In: Proceedings of SPIE the International Society for Optical Engineering. 2022.
Huber, A. I., et al. “CCAT-prime: Optical and cryogenic design of the 850 GHz module for Prime-Cam.” Proceedings of SPIE the International Society for Optical Engineering, vol. 12190, 2022. Scopus, doi:10.1117/12.2630370.
Huber AI, Chapman SC, Sinclair AK, Spencer LD, Austermann JE, Choi SK, Devina J, Gallardo PA, Henke D, Huber ZB, Keller B, Li Y, Lin LT, Niemack M, Rossi KM, Vavagiakis EM, Wheeler JD. CCAT-prime: Optical and cryogenic design of the 850 GHz module for Prime-Cam. Proceedings of SPIE the International Society for Optical Engineering. 2022.
Published In
Proceedings of SPIE the International Society for Optical Engineering
DOI
EISSN
1996-756X
ISSN
0277-786X
Publication Date
January 1, 2022
Volume
12190
Related Subject Headings
- 5102 Atomic, molecular and optical physics
- 4009 Electronics, sensors and digital hardware
- 4006 Communications engineering