Skip to main content

In Vivo Demonstration of a Real-Time Temporal SNR Acoustic Output Adjustment Method.

Publication ,  Journal Article
Huber, MT; Bradway, DP; McNally, PJ; Ellestad, SC; Trahey, GE
Published in: IEEE Trans Ultrason Ferroelectr Freq Control
August 2024

This work proposes a novel method of temporal signal-to-noise ratio (SNR)-guided adaptive acoustic output adjustment and demonstrates this approach during in vivo fetal imaging. Acoustic output adjustment is currently the responsibility of sonographers, but ultrasound safety studies show recommended as low as reasonably achievable (ALARA) practices are inconsistently followed. This study explores an automated ALARA method that adjusts the mechanical index (MI) output, targeting imaging conditions matching the temporal noise perception threshold. A 28-dB threshold SNR is used as the target SNR, following prior work showing relevant noise quantities are imperceptible once this image data quality level is reached. After implementing adaptive output adjustment on a clinical system, the average MI required to achieve 28-dB SNR in an 11-volunteer fetal abdomen imaging test ranged from 0.17 to 0.26. The higher MI levels were required when imaging at higher frequencies. During tests with 20-s MI adjustment imaging periods, the degree of motion impacted the adaptive performance. For stationary imaging views, target SNR levels were maintained in 90% of SNR evaluations. When scanning between targets the imaging conditions were more variable, but the target SNR was still maintained in 71% of the evaluations. Given the relatively low MI recommended when performing MI adjustment and the successful adjustment of MI in response to changing imaging conditions, these results encourage adoption of adaptive acoustic output approaches guided by temporal SNR.

Duke Scholars

Published In

IEEE Trans Ultrason Ferroelectr Freq Control

DOI

EISSN

1525-8955

Publication Date

August 2024

Volume

71

Issue

8

Start / End Page

960 / 971

Location

United States

Related Subject Headings

  • Ultrasonography, Prenatal
  • Signal-To-Noise Ratio
  • Signal Processing, Computer-Assisted
  • Pregnancy
  • Image Processing, Computer-Assisted
  • Humans
  • Female
  • Acoustics
  • 51 Physical sciences
  • 40 Engineering
 

Citation

APA
Chicago
ICMJE
MLA
NLM
Huber, M. T., Bradway, D. P., McNally, P. J., Ellestad, S. C., & Trahey, G. E. (2024). In Vivo Demonstration of a Real-Time Temporal SNR Acoustic Output Adjustment Method. IEEE Trans Ultrason Ferroelectr Freq Control, 71(8), 960–971. https://doi.org/10.1109/TUFFC.2024.3402530
Huber, Matthew T., David P. Bradway, Patricia J. McNally, Sarah C. Ellestad, and Gregg E. Trahey. “In Vivo Demonstration of a Real-Time Temporal SNR Acoustic Output Adjustment Method.IEEE Trans Ultrason Ferroelectr Freq Control 71, no. 8 (August 2024): 960–71. https://doi.org/10.1109/TUFFC.2024.3402530.
Huber MT, Bradway DP, McNally PJ, Ellestad SC, Trahey GE. In Vivo Demonstration of a Real-Time Temporal SNR Acoustic Output Adjustment Method. IEEE Trans Ultrason Ferroelectr Freq Control. 2024 Aug;71(8):960–71.
Huber, Matthew T., et al. “In Vivo Demonstration of a Real-Time Temporal SNR Acoustic Output Adjustment Method.IEEE Trans Ultrason Ferroelectr Freq Control, vol. 71, no. 8, Aug. 2024, pp. 960–71. Pubmed, doi:10.1109/TUFFC.2024.3402530.
Huber MT, Bradway DP, McNally PJ, Ellestad SC, Trahey GE. In Vivo Demonstration of a Real-Time Temporal SNR Acoustic Output Adjustment Method. IEEE Trans Ultrason Ferroelectr Freq Control. 2024 Aug;71(8):960–971.

Published In

IEEE Trans Ultrason Ferroelectr Freq Control

DOI

EISSN

1525-8955

Publication Date

August 2024

Volume

71

Issue

8

Start / End Page

960 / 971

Location

United States

Related Subject Headings

  • Ultrasonography, Prenatal
  • Signal-To-Noise Ratio
  • Signal Processing, Computer-Assisted
  • Pregnancy
  • Image Processing, Computer-Assisted
  • Humans
  • Female
  • Acoustics
  • 51 Physical sciences
  • 40 Engineering