Synthetic Mesh Reconstruction of Chronic, Native Quadriceps Tendon Disruptions following Failed Primary Repair.

Publication ,  Journal Article
Hartline, BE; Wilson, JM; Schwartz, AM; Roberson, JR; Guild, GN
Published in: Case Rep Orthop
2021

CASE: Two patients presented with chronic knee extensor mechanism disruption after failed primary repairs. Both patients had minimal ambulatory knee function prior to surgical intervention and were treated with a synthetic mesh reconstruction of their extensor mechanism. Our technique has been modified from previously described techniques used in revision knee arthroplasty. At the one-year follow-up, both patients had improvement in their active range of motion and had returned to their previous activity. CONCLUSION: Synthetic mesh reconstruction of chronic extensor mechanism disruption is a viable technique that can be utilized as salvage for the persistently dysfunctional native knee.

Duke Scholars

Published In

Case Rep Orthop

DOI

ISSN

2090-6749

Publication Date

2021

Volume

2021

Start / End Page

5525319

Location

United States
 

Citation

APA
Chicago
ICMJE
MLA
NLM
Hartline, B. E., Wilson, J. M., Schwartz, A. M., Roberson, J. R., & Guild, G. N. (2021). Synthetic Mesh Reconstruction of Chronic, Native Quadriceps Tendon Disruptions following Failed Primary Repair. Case Rep Orthop, 2021, 5525319. https://doi.org/10.1155/2021/5525319
Hartline, Braden E., Jacob M. Wilson, Andrew M. Schwartz, James R. Roberson, and George N. Guild. “Synthetic Mesh Reconstruction of Chronic, Native Quadriceps Tendon Disruptions following Failed Primary Repair.Case Rep Orthop 2021 (2021): 5525319. https://doi.org/10.1155/2021/5525319.
Hartline BE, Wilson JM, Schwartz AM, Roberson JR, Guild GN. Synthetic Mesh Reconstruction of Chronic, Native Quadriceps Tendon Disruptions following Failed Primary Repair. Case Rep Orthop. 2021;2021:5525319.
Hartline, Braden E., et al. “Synthetic Mesh Reconstruction of Chronic, Native Quadriceps Tendon Disruptions following Failed Primary Repair.Case Rep Orthop, vol. 2021, 2021, p. 5525319. Pubmed, doi:10.1155/2021/5525319.
Hartline BE, Wilson JM, Schwartz AM, Roberson JR, Guild GN. Synthetic Mesh Reconstruction of Chronic, Native Quadriceps Tendon Disruptions following Failed Primary Repair. Case Rep Orthop. 2021;2021:5525319.