Skip to main content

Rapid B1-Insensitive MR Fingerprinting for Quantitative Kidney Imaging.

Publication ,  Journal Article
MacAskill, CJ; Markley, M; Farr, S; Parsons, A; Perino, JR; McBennett, K; Kutney, K; Drumm, ML; Pritts, N; Griswold, MA; Ma, D; Dell, KM ...
Published in: Radiology
August 2021

Background MR fingerprinting (MRF) provides rapid and simultaneous quantification of multiple tissue parameters in a single scan. Purpose To evaluate a rapid kidney MRF technique at 3.0 T in phantoms, healthy volunteers, and patients. Materials and Methods A 15-second kidney MRF acquisition was designed with 12 acquisition segments, a range of low flip angles (5°-12°), multiple magnetization preparation schema (T1, T2, and fat suppression), and an undersampled spiral trajectory. This technique was first validated in vitro using standardized T1 and T2 phantoms. Kidney T1 and T2 maps were then obtained for 10 healthy adult volunteers (mean age ± standard deviation, 35 years ± 13; six men) and three pediatric patients with autosomal recessive polycystic kidney disease (ARPKD) (mean age, 10 years ± 3; two boys) between August 2019 and October 2020 to evaluate the method in vivo. Results Results in nine phantoms showed good agreement with spin-echo-based T1 and T2 values (R2 > 0.99). In vivo MRF kidney T1 and T2 assessments in healthy adult volunteers (cortex: T1, 1362 msec ± 5; T2, 64 msec ± 5; medulla: T1, 1827 msec ± 94; T2, 69 msec ± 3) were consistent with values in the literature but with improved precision in comparison with prior MRF implementations. In vivo MRF-based kidney T1 and T2 values with and without B1 correction were in good agreement (R2 > 0.96, P < .001), demonstrating limited sensitivity to B1 field inhomogeneities. Additional MRF reconstructions using the first nine segments of the MRF profiles (11-second acquisition time) were in good agreement with the reconstructions using 12 segments (15-second acquisition time) (R2 > 0.87, P < .001). Repeat kidney MRF scans for the three patients with ARPKD on successive days also demonstrated good reproducibility (T1 and T2: <3% difference). Conclusion A kidney MR fingerprinting method provided in vivo kidney T1 and T2 maps at 3.0 T in a single breath hold with improved precision and no need for B1 correction. © RSNA, 2021 Online supplemental material is available for this article. See also the editorial by Laustsen in this issue.

Duke Scholars

Altmetric Attention Stats
Dimensions Citation Stats

Published In

Radiology

DOI

EISSN

1527-1315

Publication Date

August 2021

Volume

300

Issue

2

Start / End Page

380 / 387

Location

United States

Related Subject Headings

  • Polycystic Kidney, Autosomal Recessive
  • Phantoms, Imaging
  • Nuclear Medicine & Medical Imaging
  • Male
  • Magnetic Resonance Imaging
  • Kidney
  • Image Processing, Computer-Assisted
  • Humans
  • Healthy Volunteers
  • Female
 

Citation

APA
Chicago
ICMJE
MLA
NLM
MacAskill, C. J., Markley, M., Farr, S., Parsons, A., Perino, J. R., McBennett, K., … Chen, Y. (2021). Rapid B1-Insensitive MR Fingerprinting for Quantitative Kidney Imaging. Radiology, 300(2), 380–387. https://doi.org/10.1148/radiol.2021202302
MacAskill, Christina J., Michael Markley, Susan Farr, Ashlee Parsons, Jacob R. Perino, Kimberly McBennett, Katherine Kutney, et al. “Rapid B1-Insensitive MR Fingerprinting for Quantitative Kidney Imaging.Radiology 300, no. 2 (August 2021): 380–87. https://doi.org/10.1148/radiol.2021202302.
MacAskill CJ, Markley M, Farr S, Parsons A, Perino JR, McBennett K, et al. Rapid B1-Insensitive MR Fingerprinting for Quantitative Kidney Imaging. Radiology. 2021 Aug;300(2):380–7.
MacAskill, Christina J., et al. “Rapid B1-Insensitive MR Fingerprinting for Quantitative Kidney Imaging.Radiology, vol. 300, no. 2, Aug. 2021, pp. 380–87. Pubmed, doi:10.1148/radiol.2021202302.
MacAskill CJ, Markley M, Farr S, Parsons A, Perino JR, McBennett K, Kutney K, Drumm ML, Pritts N, Griswold MA, Ma D, Dell KM, Flask CA, Chen Y. Rapid B1-Insensitive MR Fingerprinting for Quantitative Kidney Imaging. Radiology. 2021 Aug;300(2):380–387.

Published In

Radiology

DOI

EISSN

1527-1315

Publication Date

August 2021

Volume

300

Issue

2

Start / End Page

380 / 387

Location

United States

Related Subject Headings

  • Polycystic Kidney, Autosomal Recessive
  • Phantoms, Imaging
  • Nuclear Medicine & Medical Imaging
  • Male
  • Magnetic Resonance Imaging
  • Kidney
  • Image Processing, Computer-Assisted
  • Humans
  • Healthy Volunteers
  • Female