Skip to main content
Journal cover image

IR TrueFISP with a golden-ratio-based radial readout: fast quantification of T1, T2, and proton density.

Publication ,  Journal Article
Ehses, P; Seiberlich, N; Ma, D; Breuer, FA; Jakob, PM; Griswold, MA; Gulani, V
Published in: Magn Reson Med
January 2013

A promising approach for the simultaneous quantification of relative proton density (M(0)), T(1), and T(2) is the inversion-recovery TrueFISP sequence, consisting of an inversion pulse followed by a series of balanced steady-state free precession acquisitions. Parameters can then be obtained from a mono-exponential fit to the series of images. However, a segmented acquisition is usually necessary, which increases the total acquisition time considerably. The goal of this study is to obtain M(0), T(1), and T(2) maps using a single-shot acquisition, with T(1) and T(2) measurements in brain that are consistent with the published literature, with a 20-fold speed improvement over the segmented approach, and at a clinically relevant spatial resolution. To this end, a single-shot inversion-recovery TrueFISP sequence was combined with a radial view-sharing technique. The parameters M(0), T(1), and T(2) were then obtained on a pixel-wise basis from a three fit parameter to the signal evolution. The accuracy of this method for quantifying these parameters is demonstrated in vivo. In addition, further corrections to the quantification necessary owing to other experimental factors, namely magnetization transfer and imperfect slice profiles, were developed. Including additional scans necessary for these corrections in the measurement protocol, the required scan time is increased from approximately 6 to 18-28 s per slice.

Duke Scholars

Altmetric Attention Stats
Dimensions Citation Stats

Published In

Magn Reson Med

DOI

EISSN

1522-2594

Publication Date

January 2013

Volume

69

Issue

1

Start / End Page

71 / 81

Location

United States

Related Subject Headings

  • Protons
  • Nuclear Medicine & Medical Imaging
  • Magnetic Resonance Imaging
  • Image Processing, Computer-Assisted
  • Humans
  • Head
  • Brain
  • 4003 Biomedical engineering
  • 0903 Biomedical Engineering
 

Citation

APA
Chicago
ICMJE
MLA
NLM
Ehses, P., Seiberlich, N., Ma, D., Breuer, F. A., Jakob, P. M., Griswold, M. A., & Gulani, V. (2013). IR TrueFISP with a golden-ratio-based radial readout: fast quantification of T1, T2, and proton density. Magn Reson Med, 69(1), 71–81. https://doi.org/10.1002/mrm.24225
Ehses, Philipp, Nicole Seiberlich, Dan Ma, Felix A. Breuer, Peter M. Jakob, Mark A. Griswold, and Vikas Gulani. “IR TrueFISP with a golden-ratio-based radial readout: fast quantification of T1, T2, and proton density.Magn Reson Med 69, no. 1 (January 2013): 71–81. https://doi.org/10.1002/mrm.24225.
Ehses P, Seiberlich N, Ma D, Breuer FA, Jakob PM, Griswold MA, et al. IR TrueFISP with a golden-ratio-based radial readout: fast quantification of T1, T2, and proton density. Magn Reson Med. 2013 Jan;69(1):71–81.
Ehses, Philipp, et al. “IR TrueFISP with a golden-ratio-based radial readout: fast quantification of T1, T2, and proton density.Magn Reson Med, vol. 69, no. 1, Jan. 2013, pp. 71–81. Pubmed, doi:10.1002/mrm.24225.
Ehses P, Seiberlich N, Ma D, Breuer FA, Jakob PM, Griswold MA, Gulani V. IR TrueFISP with a golden-ratio-based radial readout: fast quantification of T1, T2, and proton density. Magn Reson Med. 2013 Jan;69(1):71–81.
Journal cover image

Published In

Magn Reson Med

DOI

EISSN

1522-2594

Publication Date

January 2013

Volume

69

Issue

1

Start / End Page

71 / 81

Location

United States

Related Subject Headings

  • Protons
  • Nuclear Medicine & Medical Imaging
  • Magnetic Resonance Imaging
  • Image Processing, Computer-Assisted
  • Humans
  • Head
  • Brain
  • 4003 Biomedical engineering
  • 0903 Biomedical Engineering