Quantification of left ventricular functional parameter values using 3D spiral bSSFP and through-time non-Cartesian GRAPPA.

Publication ,  Journal Article
Barkauskas, KJ; Rajiah, P; Ashwath, R; Hamilton, JI; Chen, Y; Ma, D; Wright, KL; Gulani, V; Griswold, MA; Seiberlich, N
Published in: J Cardiovasc Magn Reson
September 11, 2014

BACKGROUND: The standard clinical acquisition for left ventricular functional parameter analysis with cardiovascular magnetic resonance (CMR) uses a multi-breathhold multi-slice segmented balanced SSFP sequence. Performing multiple long breathholds in quick succession for ventricular coverage in the short-axis orientation can lead to fatigue and is challenging in patients with severe cardiac or respiratory disorders. This study combines the encoding efficiency of a six-fold undersampled 3D stack of spirals balanced SSFP sequence with 3D through-time spiral GRAPPA parallel imaging reconstruction. This 3D spiral method requires only one breathhold to collect the dynamic data. METHODS: Ten healthy volunteers were recruited for imaging at 3 T. The 3D spiral technique was compared against 2D imaging in terms of systolic left ventricular functional parameter values (Bland-Altman plots), total scan time (Welch's t-test) and qualitative image rating scores (Wilcoxon signed-rank test). RESULTS: Systolic left ventricular functional values were not significantly different (i.e. 3D-2D) between the methods. The 95% confidence interval for ejection fraction was -0.1 ± 1.6% (mean ± 1.96*SD). The total scan time for the 3D spiral technique was 48 s, which included one breathhold with an average duration of 14 s for the dynamic scan, plus 34 s to collect the calibration data under free-breathing conditions. The 2D method required an average of 5 min 40s for the same coverage of the left ventricle. The difference between 3D and 2D image rating scores was significantly different from zero (Wilcoxon signed-rank test, p < 0.05); however, the scores were at least 3 (i.e. average) or higher for 3D spiral imaging. CONCLUSION: The 3D through-time spiral GRAPPA method demonstrated equivalent systolic left ventricular functional parameter values, required significantly less total scan time and yielded acceptable image quality with respect to the 2D segmented multi-breathhold standard in this study. Moreover, the 3D spiral technique used just one breathhold for dynamic imaging, which is anticipated to reduce patient fatigue as part of the complete cardiac examination in future studies that include patients.

Duke Scholars

Altmetric Attention Stats
Dimensions Citation Stats

Published In

J Cardiovasc Magn Reson

DOI

EISSN

1532-429X

Publication Date

September 11, 2014

Volume

16

Issue

1

Start / End Page

65

Location

England

Related Subject Headings

  • Ventricular Function, Left
  • Time Factors
  • Systole
  • Stroke Volume
  • Predictive Value of Tests
  • Nuclear Medicine & Medical Imaging
  • Magnetic Resonance Imaging, Cine
  • Imaging, Three-Dimensional
  • Image Interpretation, Computer-Assisted
  • Humans
 

Citation

APA
Chicago
ICMJE
MLA
NLM
Barkauskas, K. J., Rajiah, P., Ashwath, R., Hamilton, J. I., Chen, Y., Ma, D., … Seiberlich, N. (2014). Quantification of left ventricular functional parameter values using 3D spiral bSSFP and through-time non-Cartesian GRAPPA. J Cardiovasc Magn Reson, 16(1), 65. https://doi.org/10.1186/s12968-014-0065-1
Barkauskas, Kestutis J., Prabhakar Rajiah, Ravi Ashwath, Jesse I. Hamilton, Yong Chen, Dan Ma, Katherine L. Wright, Vikas Gulani, Mark A. Griswold, and Nicole Seiberlich. “Quantification of left ventricular functional parameter values using 3D spiral bSSFP and through-time non-Cartesian GRAPPA.J Cardiovasc Magn Reson 16, no. 1 (September 11, 2014): 65. https://doi.org/10.1186/s12968-014-0065-1.
Barkauskas KJ, Rajiah P, Ashwath R, Hamilton JI, Chen Y, Ma D, et al. Quantification of left ventricular functional parameter values using 3D spiral bSSFP and through-time non-Cartesian GRAPPA. J Cardiovasc Magn Reson. 2014 Sep 11;16(1):65.
Barkauskas, Kestutis J., et al. “Quantification of left ventricular functional parameter values using 3D spiral bSSFP and through-time non-Cartesian GRAPPA.J Cardiovasc Magn Reson, vol. 16, no. 1, Sept. 2014, p. 65. Pubmed, doi:10.1186/s12968-014-0065-1.
Barkauskas KJ, Rajiah P, Ashwath R, Hamilton JI, Chen Y, Ma D, Wright KL, Gulani V, Griswold MA, Seiberlich N. Quantification of left ventricular functional parameter values using 3D spiral bSSFP and through-time non-Cartesian GRAPPA. J Cardiovasc Magn Reson. 2014 Sep 11;16(1):65.
Journal cover image

Published In

J Cardiovasc Magn Reson

DOI

EISSN

1532-429X

Publication Date

September 11, 2014

Volume

16

Issue

1

Start / End Page

65

Location

England

Related Subject Headings

  • Ventricular Function, Left
  • Time Factors
  • Systole
  • Stroke Volume
  • Predictive Value of Tests
  • Nuclear Medicine & Medical Imaging
  • Magnetic Resonance Imaging, Cine
  • Imaging, Three-Dimensional
  • Image Interpretation, Computer-Assisted
  • Humans