Skip to main content
Journal cover image

Impact of image formation factors on material discrimination in spectral CT.

Publication ,  Journal Article
Rajagopal, J; Zarei, M; Vrbaski, S; Pritchard, WF; Abadi, E; Jones, EC; Samei, E
Published in: Phys Med Biol
December 24, 2024

Objective.The accuracy of material decomposition in spectral computed tomography (CT) depends on the information quality captured in image acquisition, a factor that cannot be adequately assessed using conventional image quality metrologies due to the multi-energy nature of spectral CT. This work used metrologies specific to spectral CT to evaluate the impact of acquisition conditions on the quality of spectral CT images and accuracy of material decomposition techniques.Approach.Computational phantoms were created with cylindrical shapes and variable sizes (20-40 cm), containing inserts of iodine and gadolinium (1-8 mg ml-1). The phantoms were imaged using a validated CT simulator modeling a clinical photon-counting CT scanner. The acquisitions were done at different detector energy thresholds (50-90 keV) and tube currents (25-250 mAs). The images were used to develop and train a data-driven material identification and quantification algorithm. Two spectral metrologies, multivariate contrast-to-noise ratio (CNR) and separability index, were used to characterize the impact of energy threshold, tube current, phantom size, and material concentration on signal quality. The results were interpreted in terms of figures of merit of accuracy for classification and mean absolute error (MAE) and root mean squared error (RMSE) for regression.Main results. Signal quality for iodine and gadolinium was maximized with a low energy threshold, high tube current, and small phantom size. While conventional CNR terms predicted variable image quality for two-thirds of all conditions, multivariate CNR was above 10 for half of those. Separability index showed that for a phantom size greater than 30 cm, a minimum of 75-110 mAs is required to separate 2 mg ml-1of iodine and gadolinium. For both classification and regression tasks, a random forest model with a local statistics dataset provided the best performance. Across conditions, classification performance was 0.66-0.99 for I accuracy, 0.72-0.99 for Gd accuracy. Regression performance was 0.02-0.91 mg ml-1I and 0.02-0.59 mg ml-1Gd for MAE and 0.11-1.08 mg ml-1I and 0.07-0.76 mg ml-1Gd for RMSE.Significance.Multivariate CNR and separability index metrologies can predict material decomposition performance. Theses metrics demonstrated that the decomposition of iodine and gadolinium have higher separability when the acquisition is done at a lower energy threshold, with a higher tube current, and when the imaged object has a smaller size. Object size had the largest impact on metrics and decomposition performance.

Duke Scholars

Published In

Phys Med Biol

DOI

EISSN

1361-6560

Publication Date

December 24, 2024

Volume

70

Issue

1

Location

England

Related Subject Headings

  • Tomography, X-Ray Computed
  • Signal-To-Noise Ratio
  • Phantoms, Imaging
  • Nuclear Medicine & Medical Imaging
  • Iodine
  • Image Processing, Computer-Assisted
  • 5105 Medical and biological physics
  • 1103 Clinical Sciences
  • 0903 Biomedical Engineering
  • 0299 Other Physical Sciences
 

Citation

APA
Chicago
ICMJE
MLA
NLM
Rajagopal, J., Zarei, M., Vrbaski, S., Pritchard, W. F., Abadi, E., Jones, E. C., & Samei, E. (2024). Impact of image formation factors on material discrimination in spectral CT. Phys Med Biol, 70(1). https://doi.org/10.1088/1361-6560/ad9daf
Rajagopal, Jayasai, Mojtaba Zarei, Stevan Vrbaski, William F. Pritchard, Ehsan Abadi, Elizabeth C. Jones, and Ehsan Samei. “Impact of image formation factors on material discrimination in spectral CT.Phys Med Biol 70, no. 1 (December 24, 2024). https://doi.org/10.1088/1361-6560/ad9daf.
Rajagopal J, Zarei M, Vrbaski S, Pritchard WF, Abadi E, Jones EC, et al. Impact of image formation factors on material discrimination in spectral CT. Phys Med Biol. 2024 Dec 24;70(1).
Rajagopal, Jayasai, et al. “Impact of image formation factors on material discrimination in spectral CT.Phys Med Biol, vol. 70, no. 1, Dec. 2024. Pubmed, doi:10.1088/1361-6560/ad9daf.
Rajagopal J, Zarei M, Vrbaski S, Pritchard WF, Abadi E, Jones EC, Samei E. Impact of image formation factors on material discrimination in spectral CT. Phys Med Biol. 2024 Dec 24;70(1).
Journal cover image

Published In

Phys Med Biol

DOI

EISSN

1361-6560

Publication Date

December 24, 2024

Volume

70

Issue

1

Location

England

Related Subject Headings

  • Tomography, X-Ray Computed
  • Signal-To-Noise Ratio
  • Phantoms, Imaging
  • Nuclear Medicine & Medical Imaging
  • Iodine
  • Image Processing, Computer-Assisted
  • 5105 Medical and biological physics
  • 1103 Clinical Sciences
  • 0903 Biomedical Engineering
  • 0299 Other Physical Sciences