Dose verification of 2 targets simultaneously for single-isocenter stereotactic radiation therapy and radiosurgery plans.

Journal articles  - Journal Article
Cui, G; Duan, J; Yin, F-F
Published in: Med Dosim

Most of conventional 2-dimensional (2D) methods verify dose of multiple targets separately one-by-one for Single-isocenter Multiple-target (SIMT) brain plans, which are inefficient and sub-optimal. This study presented a practical method to verify the dose of 2 targets simultaneously for improved efficiency and accuracy. Fifteen Stereotactic Radiation Therapy (SRT) and sixteen Stereotactic Radiosurgery (SRS) plans were used for this study. Each plan has 2 targets coincide with a plane through the plan isocenter. All plans were created in the Eclipse Treatment Planning System (TPS) using a 6 MV flattening filter free photon beam. A 2D detector array, myQA SRS was used for measurements. It has a spatial resolution of 0.4 mm and an active area of 120 × 140 mm2. It can be rotated along the longitudinal axis with a cylindrical phantom with one-degree precision. All plans were delivered with the detector array centered at the plan isocenter and rotated to intersect 2 targets. Six plans with target separations less than 70 mm were crosschecked with the SRS MapCHECK, which has an active area of 77 × 77 mm2. The measured 2D dose distributions were compared with those calculated from the TPS. Gamma-index analysis was performed using 3%/1 mm criteria and a 10% dose threshold. For all 31 SIMT brain plans measured with myQA SRS, the average and standard deviation of the gamma-passing rate was (96.8 ± 2.2)%. For 15 SRT plans and 16 SRS plans, that was (96.6 ± 2.4)% and (97.0 ± 2.1)%, respectively. For 6 plans crosschecked, the average gamma-passing rates were 96.8% vs. 94.8% with myQA SRS and SRS MapCHECK, respectively. A practical method to verify the dose of 2 targets simultaneously was demonstrated. It offers an efficient way for pretreatment verification of SIMT SRT and SRS plans with improved accuracy.

Duke Scholars

Altmetric Attention Stats
Dimensions Citation Stats

Published In

Med Dosim

DOI

EISSN

1873-4022

Volume

50

Issue

2

Start / End Page

179 / 184

Location

United States

Related Subject Headings

  • Radiotherapy Planning, Computer-Assisted
  • Radiotherapy Dosage
  • Radiosurgery
  • Phantoms, Imaging
  • Oncology & Carcinogenesis
  • Humans
  • Brain Neoplasms
  • 5105 Medical and biological physics
  • 3211 Oncology and carcinogenesis
 

Citation

APA
Chicago
ICMJE
MLA
NLM
Cui, G., Duan, J., & Yin, F.-F. (n.d.). Dose verification of 2 targets simultaneously for single-isocenter stereotactic radiation therapy and radiosurgery plans. Med Dosim, 50(2), 179–184. https://doi.org/10.1016/j.meddos.2024.12.006
Cui, Guoqiang, Jun Duan, and Fang-Fang Yin. “Dose verification of 2 targets simultaneously for single-isocenter stereotactic radiation therapy and radiosurgery plans.Med Dosim 50, no. 2 (n.d.): 179–84. https://doi.org/10.1016/j.meddos.2024.12.006.
Cui, Guoqiang, et al. “Dose verification of 2 targets simultaneously for single-isocenter stereotactic radiation therapy and radiosurgery plans.Med Dosim, vol. 50, no. 2, pp. 179–84. Pubmed, doi:10.1016/j.meddos.2024.12.006.
Journal cover image

Published In

Med Dosim

DOI

EISSN

1873-4022

Volume

50

Issue

2

Start / End Page

179 / 184

Location

United States

Related Subject Headings

  • Radiotherapy Planning, Computer-Assisted
  • Radiotherapy Dosage
  • Radiosurgery
  • Phantoms, Imaging
  • Oncology & Carcinogenesis
  • Humans
  • Brain Neoplasms
  • 5105 Medical and biological physics
  • 3211 Oncology and carcinogenesis