Comparison of different reference values for lung function: implications of inconsistent use among centers.

Publication ,  Journal Article
Mangseth, H; Sikkeland, LIB; Durheim, MT; Ulvestad, M; Myrdal, OH; Kongerud, J; Lund, MB
Published in: BMC pulmonary medicine
April 2023

For interpretation of pulmonary function tests (PFTs), reference values based on sex, age, height and ethnicity are needed. In Norway, the European Coal and Steel Community (ECSC) reference values remain widely used, in spite of recommendations to implement the more recent Global Lung Function Initiative (GLI) reference values.To assess the effects of changing from ECSC to GLI reference values for spirometry, DLCO and static lung volumes, using a clinical cohort of adults with a broad range in age and lung function.PFTs from 577 adults (18-85 years, 45% females) included in recent clinical studies were used to compare ECSC and GLI reference values for FVC, FEV1, DLCO, TLC and RV. Percent predicted and lower limit of normal (LLN) were calculated. Bland-Altman plots were used to assess agreement between GLI and ECSC % predicted values.In both sexes, GLI % predicted values were lower for FVC and FEV1, and higher for DLCO and RV, compared to ECSC. The disagreement was most pronounced in females, with mean (SD) difference 15 (5) percent points (pp) for DLCO and 17 (9) pp for RV (p < 0.001). With GLI, DLCO was below LLN in 23% of the females, with ECSC in 49% of the females.The observed differences between GLI and ECSC reference values are likely to entail significant consequences with respect to criteria for diagnostics and treatment, health care benefits and inclusion in clinical trials. To ensure equity of care, the same reference values should be consistently implemented across centers nationwide.

Duke Scholars

Published In

BMC pulmonary medicine

DOI

EISSN

1471-2466

ISSN

1471-2466

Publication Date

April 2023

Volume

23

Issue

1

Start / End Page

137

Related Subject Headings

  • Vital Capacity
  • Spirometry
  • Respiratory System
  • Respiratory Physiological Phenomena
  • Respiratory Function Tests
  • Reference Values
  • Male
  • Lung
  • Humans
  • Forced Expiratory Volume
 

Citation

APA
Chicago
ICMJE
MLA
NLM
Mangseth, H., Sikkeland, L. I. B., Durheim, M. T., Ulvestad, M., Myrdal, O. H., Kongerud, J., & Lund, M. B. (2023). Comparison of different reference values for lung function: implications of inconsistent use among centers. BMC Pulmonary Medicine, 23(1), 137. https://doi.org/10.1186/s12890-023-02430-7
Mangseth, Henrik, Liv Ingunn Bjoner Sikkeland, Michael Thomas Durheim, Mariann Ulvestad, Ole Henrik Myrdal, Johny Kongerud, and May B. Lund. “Comparison of different reference values for lung function: implications of inconsistent use among centers.BMC Pulmonary Medicine 23, no. 1 (April 2023): 137. https://doi.org/10.1186/s12890-023-02430-7.
Mangseth H, Sikkeland LIB, Durheim MT, Ulvestad M, Myrdal OH, Kongerud J, et al. Comparison of different reference values for lung function: implications of inconsistent use among centers. BMC pulmonary medicine. 2023 Apr;23(1):137.
Mangseth, Henrik, et al. “Comparison of different reference values for lung function: implications of inconsistent use among centers.BMC Pulmonary Medicine, vol. 23, no. 1, Apr. 2023, p. 137. Epmc, doi:10.1186/s12890-023-02430-7.
Mangseth H, Sikkeland LIB, Durheim MT, Ulvestad M, Myrdal OH, Kongerud J, Lund MB. Comparison of different reference values for lung function: implications of inconsistent use among centers. BMC pulmonary medicine. 2023 Apr;23(1):137.
Journal cover image

Published In

BMC pulmonary medicine

DOI

EISSN

1471-2466

ISSN

1471-2466

Publication Date

April 2023

Volume

23

Issue

1

Start / End Page

137

Related Subject Headings

  • Vital Capacity
  • Spirometry
  • Respiratory System
  • Respiratory Physiological Phenomena
  • Respiratory Function Tests
  • Reference Values
  • Male
  • Lung
  • Humans
  • Forced Expiratory Volume