The purpose of this Medical Physics Practice Guideline (MPPG) is to describe the minimum level of medical physics support deemed prudent for the practice of linear-accelerator, photon-based (linac) stereotactic radiosurgery (SRS), and stereotactic body radiation therapy (SBRT) services. This report is an update of MPPG 9.a1 published in 2017. As SRS and SBRT services are rapidly adopted into the community-practice setting, this guideline has been developed to build on the work presented in MPPG 9.a and provide current appropriate minimum practice guidelines for such services.

Duke Scholars

Published In

J Appl Clin Med Phys

DOI

EISSN

1526-9914

Publication Date

April 2025

Volume

26

Issue

4

Start / End Page

e14624

Location

United States

Related Subject Headings

  • Radiotherapy, Intensity-Modulated
  • Radiotherapy Planning, Computer-Assisted
  • Radiotherapy Dosage
  • Radiosurgery
  • Practice Guidelines as Topic
  • Particle Accelerators
  • Nuclear Medicine & Medical Imaging
  • Neoplasms
  • Humans
  • Health Physics
 

Citation

APA
Chicago
ICMJE
MLA
NLM
Cirino, E., Benedict, S. H., Dupre, P. J., Halvorsen, P. H., Kim, G.-Y., Reyhan, M. L., … Yoo, S. (2025). AAPM-RSS Medical Physics Practice Guideline 9.b: SRS-SBRT. J Appl Clin Med Phys, 26(4), e14624. https://doi.org/10.1002/acm2.14624
Cirino, Eileen, Stanley H. Benedict, Pamela J. Dupre, Per H. Halvorsen, Grace Gwe-Ya Kim, Meral L. Reyhan, Christopher W. Schneider, Lei Wang, Carl P. Weaver, and Sua Yoo. “AAPM-RSS Medical Physics Practice Guideline 9.b: SRS-SBRT.J Appl Clin Med Phys 26, no. 4 (April 2025): e14624. https://doi.org/10.1002/acm2.14624.
Cirino E, Benedict SH, Dupre PJ, Halvorsen PH, Kim GG-Y, Reyhan ML, et al. AAPM-RSS Medical Physics Practice Guideline 9.b: SRS-SBRT. J Appl Clin Med Phys. 2025 Apr;26(4):e14624.
Cirino, Eileen, et al. “AAPM-RSS Medical Physics Practice Guideline 9.b: SRS-SBRT.J Appl Clin Med Phys, vol. 26, no. 4, Apr. 2025, p. e14624. Pubmed, doi:10.1002/acm2.14624.
Cirino E, Benedict SH, Dupre PJ, Halvorsen PH, Kim GG-Y, Reyhan ML, Schneider CW, Wang L, Weaver CP, Yoo S. AAPM-RSS Medical Physics Practice Guideline 9.b: SRS-SBRT. J Appl Clin Med Phys. 2025 Apr;26(4):e14624.

Published In

J Appl Clin Med Phys

DOI

EISSN

1526-9914

Publication Date

April 2025

Volume

26

Issue

4

Start / End Page

e14624

Location

United States

Related Subject Headings

  • Radiotherapy, Intensity-Modulated
  • Radiotherapy Planning, Computer-Assisted
  • Radiotherapy Dosage
  • Radiosurgery
  • Practice Guidelines as Topic
  • Particle Accelerators
  • Nuclear Medicine & Medical Imaging
  • Neoplasms
  • Humans
  • Health Physics