SU‐FF‐T‐273: Energy Dependence of TLD‐100 Chips and Microcubes for the Xoft Axxent® 50 KV Miniature X‐Ray Source and Cs‐137 Relative to Co‐60

Publication ,  Conference
Pike, T; Raffi, J; Davis, S; Dewerd, L
Published in: Medical Physics
January 1, 2009

Purpose: To use experimental methods to measure the overall energy dependence of LiF:Mg,Ti thermoluminescent dosimeters (TLDs) for the Xoft Axxent® miniature x‐ray source (mean energy ∼27 keV) and 137Cs (662 keV) relative to 60Co (1250 keV), to calculate the absorbed‐dose energy dependence with the Monte Carlo (MC) code MCNP5, and to determine the intrinsic energy dependence of the TLDs by dividing the measured overall energy dependence by the absorbed‐dose energy dependence. Method and Materials: TLDs were irradiated to a known air kerma with all three sources. The air kerma rate of the miniature x‐ray source was measured using an Attix free‐air chamber. Each irradiation was performed for TLDs of two different sizes, microcubes (1 mm3) and chips (3×3×1 mm3). MC simulations were performed for each setup to calculate dose to the TLDs including photon scatter from the holders. MC methods were also used to calculate the air kerma. Results: The overall measured energy response was greater than the MC calculated absorbed‐dose energy dependence for both sources and both chip sizes. The difference between the measured and calculated energy dependence for the miniature x‐ray source was greater than for 137Cs, which means that the intrinsic energy dependence of LiF:Mg,Ti TLD chips and microcubes relative to 60Co is more pronounced at lower energies. Conclusion: This experiment provides further evidence that TLDs have intrinsic energy dependence in addition to the absorbed‐dose energy dependence that can be calculated using Monte Carlo methods. MC corrections alone are not able to calculate the overall energy dependence of TLDs. Therefore, appropriate energy dependence corrections must be measured and applied to TLD measurements when calibration irradiations are performed at a different energy. Conflict of Interest: This research was partially sponsored by Xoft, Inc. © 2009, American Association of Physicists in Medicine. All rights reserved.

Duke Scholars

Published In

Medical Physics

DOI

ISSN

0094-2405

Publication Date

January 1, 2009

Volume

36

Issue

6

Start / End Page

2583 / 2584

Related Subject Headings

  • Nuclear Medicine & Medical Imaging
  • 5105 Medical and biological physics
  • 4003 Biomedical engineering
  • 1112 Oncology and Carcinogenesis
  • 0903 Biomedical Engineering
  • 0299 Other Physical Sciences
 

Citation

APA
Chicago
ICMJE
MLA
NLM
Pike, T., Raffi, J., Davis, S., & Dewerd, L. (2009). SU‐FF‐T‐273: Energy Dependence of TLD‐100 Chips and Microcubes for the Xoft Axxent® 50 KV Miniature X‐Ray Source and Cs‐137 Relative to Co‐60. In Medical Physics (Vol. 36, pp. 2583–2584). https://doi.org/10.1118/1.3181750
Pike, T., J. Raffi, S. Davis, and L. Dewerd. “SU‐FF‐T‐273: Energy Dependence of TLD‐100 Chips and Microcubes for the Xoft Axxent® 50 KV Miniature X‐Ray Source and Cs‐137 Relative to Co‐60.” In Medical Physics, 36:2583–84, 2009. https://doi.org/10.1118/1.3181750.
Pike, T., et al. “SU‐FF‐T‐273: Energy Dependence of TLD‐100 Chips and Microcubes for the Xoft Axxent® 50 KV Miniature X‐Ray Source and Cs‐137 Relative to Co‐60.” Medical Physics, vol. 36, no. 6, 2009, pp. 2583–84. Scopus, doi:10.1118/1.3181750.

Published In

Medical Physics

DOI

ISSN

0094-2405

Publication Date

January 1, 2009

Volume

36

Issue

6

Start / End Page

2583 / 2584

Related Subject Headings

  • Nuclear Medicine & Medical Imaging
  • 5105 Medical and biological physics
  • 4003 Biomedical engineering
  • 1112 Oncology and Carcinogenesis
  • 0903 Biomedical Engineering
  • 0299 Other Physical Sciences