Skip to main content

Ventral hernia repair with T-line hernia mesh: A multi-institutional experience.

Publication ,  Journal Article
Emovon, EO; Oyola, AM; Arias-Espinosa, L; Naga, HI; Volk, AS; Hope, W; Malcher, F; Levine, JP; Harris, HW; Yoo, J; Patel, A
Published in: Surg Pract Sci
June 2025

INTRODUCTION: Ventral hernia repair (VHR) is a common procedure complicated by high hernia recurrence rates exceeding 30 % over ten years. The T-Line® Hernia Mesh is a synthetic, polypropylene mesh featuring mesh extensions designed to prevent anchor point failure by evenly distributing tension to reduce ventral hernia recurrences. This study evaluates the outcomes of the T-Line® mesh in VHR with 1-3 year follow-up. METHODS: This study is a multi-institutional retrospective cohort study on patients who underwent VHR with T-Line® mesh between October 2020 and December 2022. Patient demographics, surgical details, and postoperative outcomes were collected. Patient-reported outcomes were assessed using HerQLes and ACHQC surveys. RESULTS: Fifty-seven patients underwent VHR with the T-Line® mesh with a median age of sixty years and BMI of 30.8 kg/m2. The median follow-up was 454 days with a range of 365 to 1192 days. The median defect area was 97.0 cm2 and mesh area was 300 cm2. Seventeen patients (29.8 %) underwent hernia repair with panniculectomy. Postoperatively, seven patients (12.3 %) presented to the emergency department within 30 days, with five patients (8.8 %) requiring readmission. Eight patients (14.0 %) experienced complications within thirty days, with the majority being surgical site infections (n = 7, 12.3 %). Of the five patients that reported feeling a slight bulge at their previous hernia site, upon clinical evaluation two patients had a recurrence (one recurrence was caused by the suture tearing through the underlying laparotomy repair while the mesh remained anchored intact above the repair, and the second recurrence was caused by inadequate mesh fixation at the caudal border of the mesh), while no patients reported using pain medication for abdominal wall discomfort. CONCLUSIONS: The T-Line® Hernia Mesh demonstrated safety and effectiveness in ventral hernia repair, with low recurrences and postoperative complications rates over a 1-3-year period, suggesting it is a valuable tool for complex hernia repairs.

Duke Scholars

Published In

Surg Pract Sci

DOI

EISSN

2666-2620

Publication Date

June 2025

Volume

21

Start / End Page

100285

Location

England
 

Citation

APA
Chicago
ICMJE
MLA
NLM
Emovon, E. O., Oyola, A. M., Arias-Espinosa, L., Naga, H. I., Volk, A. S., Hope, W., … Patel, A. (2025). Ventral hernia repair with T-line hernia mesh: A multi-institutional experience. Surg Pract Sci, 21, 100285. https://doi.org/10.1016/j.sipas.2025.100285
Emovon, Emmanuel O., Anna Malysz Oyola, Luis Arias-Espinosa, Hani I. Naga, Angela S. Volk, William Hope, Flavio Malcher, et al. “Ventral hernia repair with T-line hernia mesh: A multi-institutional experience.Surg Pract Sci 21 (June 2025): 100285. https://doi.org/10.1016/j.sipas.2025.100285.
Emovon EO, Oyola AM, Arias-Espinosa L, Naga HI, Volk AS, Hope W, et al. Ventral hernia repair with T-line hernia mesh: A multi-institutional experience. Surg Pract Sci. 2025 Jun;21:100285.
Emovon, Emmanuel O., et al. “Ventral hernia repair with T-line hernia mesh: A multi-institutional experience.Surg Pract Sci, vol. 21, June 2025, p. 100285. Pubmed, doi:10.1016/j.sipas.2025.100285.
Emovon EO, Oyola AM, Arias-Espinosa L, Naga HI, Volk AS, Hope W, Malcher F, Levine JP, Harris HW, Yoo J, Patel A. Ventral hernia repair with T-line hernia mesh: A multi-institutional experience. Surg Pract Sci. 2025 Jun;21:100285.

Published In

Surg Pract Sci

DOI

EISSN

2666-2620

Publication Date

June 2025

Volume

21

Start / End Page

100285

Location

England