PURPOSE: This study investigates the imaging performance of a deep silicon-based photon-counting CT (Si-PCCT) in quantifying iodine contrast through a virtual imaging trial (VIT). METHODS: We developed a VIT framework using Si-PCCT simulator and benchmarked it against a prototype using an ACR phantom for assessing spatial resolution and noise characteristics, and a geometric phantom for iodine quantification. We imaged geometrical phantoms (20 - 40 cm) with iodine concentrations ranging from 1 to 19.7 mg/ml and XCAT human models with iodine contrast at BMI of 19 to 38 kg/m2 across different radiation dose levels (13.9, 27.8, and 41.7 mGy of CTDIvol). We performed material decomposition, reconstructed iodine CT images, and evaluated iodine quantification accuracy. RESULTS: The Si-PCCT simulator closely matched with the prototype, with differences within 3 % in MTF (f50 and f10) and 3.7 % (fpeak) in NNPS, and Root-Mean-Square Error of 0.12 mg/ml in iodine quantification. The mean absolute errors (MAE) between the estimated and ground-truth iodine concentration were 0.10, 0.25, and 1.80 mg/ml for 20, 30, and 40 cm phantoms, and 0.31, 0.37, and 0.70 mg/ml for XCAT human models with BMIs of 19, 28, and 38 kg/m2, respectively. Similarly, the MAEs were 0.88, 0.45, and 0.31 mg/ml for the geometrical phantoms, and 0.66, 0.5, and 0.46 mg/ml for human models at CTDIvol of 13.9, 27.8, and 41.7 mGy respectively. These results demonstrate accurate iodine quantification performance, influenced by object size and radiation dose. CONCLUSION: This study shows the promising clinical utility of Si-PCCT for accurate iodine quantification under clinically relevant imaging conditions.

Duke Scholars

Published In

Phys Med

DOI

EISSN

1724-191X

Publication Date

July 2025

Volume

135

Start / End Page

105003

Location

Italy

Related Subject Headings

  • Tomography, X-Ray Computed
  • Silicon
  • Radiation Dosage
  • Photons
  • Phantoms, Imaging
  • Nuclear Medicine & Medical Imaging
  • Iodine
  • Image Processing, Computer-Assisted
  • Humans
  • 5105 Medical and biological physics
 

Citation

APA
Chicago
ICMJE
MLA
NLM
Panta, R. K., Yin, Z., Grönberg, F., Bhattarai, M., Abadi, E., Segars, P., & Samei, E. (2025). Iodine quantification performance with deep silicon-based Photon-Counting CT: A virtual imaging trial study. Phys Med, 135, 105003. https://doi.org/10.1016/j.ejmp.2025.105003
Panta, Raj Kumar, Zhye Yin, Fredrik Grönberg, Mridul Bhattarai, Ehsan Abadi, Paul Segars, and Ehsan Samei. “Iodine quantification performance with deep silicon-based Photon-Counting CT: A virtual imaging trial study.Phys Med 135 (July 2025): 105003. https://doi.org/10.1016/j.ejmp.2025.105003.
Panta RK, Yin Z, Grönberg F, Bhattarai M, Abadi E, Segars P, et al. Iodine quantification performance with deep silicon-based Photon-Counting CT: A virtual imaging trial study. Phys Med. 2025 Jul;135:105003.
Panta, Raj Kumar, et al. “Iodine quantification performance with deep silicon-based Photon-Counting CT: A virtual imaging trial study.Phys Med, vol. 135, July 2025, p. 105003. Pubmed, doi:10.1016/j.ejmp.2025.105003.
Panta RK, Yin Z, Grönberg F, Bhattarai M, Abadi E, Segars P, Samei E. Iodine quantification performance with deep silicon-based Photon-Counting CT: A virtual imaging trial study. Phys Med. 2025 Jul;135:105003.

Published In

Phys Med

DOI

EISSN

1724-191X

Publication Date

July 2025

Volume

135

Start / End Page

105003

Location

Italy

Related Subject Headings

  • Tomography, X-Ray Computed
  • Silicon
  • Radiation Dosage
  • Photons
  • Phantoms, Imaging
  • Nuclear Medicine & Medical Imaging
  • Iodine
  • Image Processing, Computer-Assisted
  • Humans
  • 5105 Medical and biological physics