Skip to main content

High-Density EEG Source Localisation of averaged interictal epileptic Discharges validated by surgical Outcome.

Publication ,  Journal Article
Vorderwülbecke, BJ; Carboni, M; Tourbier, S; Spinelli, L; Brunet, D; Seeber, M; Korff, CM; Momjian, S; Vargas, M; Seeck, M; Vulliemoz, S; Wirsich, J
Published in: Sci Data
August 16, 2025

Electroencephalographic source localisation (ESL) of interictal epileptiform discharges is a valuable tool for presurgical evaluation of pharmacoresistant focal epilepsy. Various forward models, inverse solutions algorithms, and software packages have been published. However, clinical validation studies are based on heterogenous end points and study cohorts. To allow comparison of different interictal ESL methods within one standardised dataset, we provide deidentified clinical data of 44 well-characterised patients with pharmacoresistant focal epilepsy and a first resective surgery, validated by 12-month postsurgical outcome. Thirty patients had favourable outcomes, including 28 with complete seizure freedom, indicating that the epileptogenic zone was correctly estimated. For each patient, pre-processed individual structural MRI, 257-channel EEG averages of homologous discharges, postsurgical structural neuroimaging, and detailed clinical and technical information are given. In patients with favourable outcomes, source maxima of averaged discharges were <10 mm remote from the resection in 67% and within a sublobe affected by the surgery in 83%. Future validation studies of new ESL approaches can be compared to this benchmark.

Duke Scholars

Published In

Sci Data

DOI

EISSN

2052-4463

Publication Date

August 16, 2025

Volume

12

Issue

1

Start / End Page

1441

Location

England

Related Subject Headings

  • Male
  • Magnetic Resonance Imaging
  • Humans
  • Female
  • Epilepsy
  • Epilepsies, Partial
  • Electroencephalography
  • Drug Resistant Epilepsy
  • Adult
 

Citation

APA
Chicago
ICMJE
MLA
NLM
Vorderwülbecke, B. J., Carboni, M., Tourbier, S., Spinelli, L., Brunet, D., Seeber, M., … Wirsich, J. (2025). High-Density EEG Source Localisation of averaged interictal epileptic Discharges validated by surgical Outcome. Sci Data, 12(1), 1441. https://doi.org/10.1038/s41597-025-05740-z
Vorderwülbecke, Bernd J., Margherita Carboni, Sebastien Tourbier, Laurent Spinelli, Denis Brunet, Martin Seeber, Christian M. Korff, et al. “High-Density EEG Source Localisation of averaged interictal epileptic Discharges validated by surgical Outcome.Sci Data 12, no. 1 (August 16, 2025): 1441. https://doi.org/10.1038/s41597-025-05740-z.
Vorderwülbecke BJ, Carboni M, Tourbier S, Spinelli L, Brunet D, Seeber M, et al. High-Density EEG Source Localisation of averaged interictal epileptic Discharges validated by surgical Outcome. Sci Data. 2025 Aug 16;12(1):1441.
Vorderwülbecke, Bernd J., et al. “High-Density EEG Source Localisation of averaged interictal epileptic Discharges validated by surgical Outcome.Sci Data, vol. 12, no. 1, Aug. 2025, p. 1441. Pubmed, doi:10.1038/s41597-025-05740-z.
Vorderwülbecke BJ, Carboni M, Tourbier S, Spinelli L, Brunet D, Seeber M, Korff CM, Momjian S, Vargas M, Seeck M, Vulliemoz S, Wirsich J. High-Density EEG Source Localisation of averaged interictal epileptic Discharges validated by surgical Outcome. Sci Data. 2025 Aug 16;12(1):1441.

Published In

Sci Data

DOI

EISSN

2052-4463

Publication Date

August 16, 2025

Volume

12

Issue

1

Start / End Page

1441

Location

England

Related Subject Headings

  • Male
  • Magnetic Resonance Imaging
  • Humans
  • Female
  • Epilepsy
  • Epilepsies, Partial
  • Electroencephalography
  • Drug Resistant Epilepsy
  • Adult