Skip to main content
construction release_alert
Scholars@Duke will be down for maintenance for approximately one hour starting Tuesday, 11/11 @1pm ET
cancel

Image Guided Mitral Valve Replacement: Registration of 3D Ultrasound and 2D X-ray Images.

Publication ,  Journal Article
Dormer, JD; Bhuiyan, FI; Rahman, N; Deaton, N; Sheng, J; Padala, M; Desai, JP; Fei, B
Published in: Proceedings of SPIE--the International Society for Optical Engineering
February 2020

Mitral valve repair or replacement is important in the treatment of mitral regurgitation. For valve replacement, a transcatheter approach had the possibility of decrease the invasiveness of the procedure while retaining the benefit of replacement over repair. However, fluoroscopy images acquired during the procedure provide no anatomical information regarding the placement of the probe tip once the catheter has entered a cardiac chamber. By using 3D ultrasound and registering the 3D ultrasound images to the fluoroscopy images, a physician can gain a greater understanding of the mitral valve region during transcatheter mitral valve replacement surgery. In this work, we present a graphical user interface which allows the registration of two co-planar X-ray images with 3D ultrasound during mitral valve replacement surgery.

Duke Scholars

Published In

Proceedings of SPIE--the International Society for Optical Engineering

DOI

EISSN

1996-756X

ISSN

0277-786X

Publication Date

February 2020

Volume

11315

Start / End Page

113150Z

Related Subject Headings

  • 5102 Atomic, molecular and optical physics
  • 4009 Electronics, sensors and digital hardware
  • 4006 Communications engineering
 

Citation

APA
Chicago
ICMJE
MLA
NLM
Dormer, J. D., Bhuiyan, F. I., Rahman, N., Deaton, N., Sheng, J., Padala, M., … Fei, B. (2020). Image Guided Mitral Valve Replacement: Registration of 3D Ultrasound and 2D X-ray Images. Proceedings of SPIE--the International Society for Optical Engineering, 11315, 113150Z. https://doi.org/10.1117/12.2549407
Dormer, James D., Fiaz Islam Bhuiyan, Nahian Rahman, Nancy Deaton, Jun Sheng, Muralidhar Padala, Jaydev P. Desai, and Baowei Fei. “Image Guided Mitral Valve Replacement: Registration of 3D Ultrasound and 2D X-ray Images.Proceedings of SPIE--the International Society for Optical Engineering 11315 (February 2020): 113150Z. https://doi.org/10.1117/12.2549407.
Dormer JD, Bhuiyan FI, Rahman N, Deaton N, Sheng J, Padala M, et al. Image Guided Mitral Valve Replacement: Registration of 3D Ultrasound and 2D X-ray Images. Proceedings of SPIE--the International Society for Optical Engineering. 2020 Feb;11315:113150Z.
Dormer, James D., et al. “Image Guided Mitral Valve Replacement: Registration of 3D Ultrasound and 2D X-ray Images.Proceedings of SPIE--the International Society for Optical Engineering, vol. 11315, Feb. 2020, p. 113150Z. Epmc, doi:10.1117/12.2549407.
Dormer JD, Bhuiyan FI, Rahman N, Deaton N, Sheng J, Padala M, Desai JP, Fei B. Image Guided Mitral Valve Replacement: Registration of 3D Ultrasound and 2D X-ray Images. Proceedings of SPIE--the International Society for Optical Engineering. 2020 Feb;11315:113150Z.

Published In

Proceedings of SPIE--the International Society for Optical Engineering

DOI

EISSN

1996-756X

ISSN

0277-786X

Publication Date

February 2020

Volume

11315

Start / End Page

113150Z

Related Subject Headings

  • 5102 Atomic, molecular and optical physics
  • 4009 Electronics, sensors and digital hardware
  • 4006 Communications engineering