Skip to main content
Journal cover image

Comparison of load-to-failure in pre-shaped versus surgeon-shaped Achilles tendon allograft bone blocks.

Publication ,  Journal Article
Edge, C; Ernst, B; Sharma, A; Savsani, K; Satalich, J; O'Neill, C; Owen, J; Goodloe, JB
Published in: J Orthop
October 2025

PURPOSE: Traditional bone-plug allografts in reconstruction of anterior cruciate ligament (ACL) tears require shaping of the bone plug by surgeons, yielding inconsistent results, greater costs, and increased operative time. We compare the load-to-failure between pre-shaped and surgeon-shaped Achilles allografts with calcaneal bone blocks to assess their use in ACL reconstruction. METHODS: Six pre-shaped Achilles allograft tendons with calcaneus bone grafts were compared to 6 surgeon-shaped allografts. Calcaneal grafts were inserted into artificial saw bone while the opposite ends were fixed to a linear-torsion dynamic test machine for cyclic and load-to-failure testing. Loading began with a preconditioning phase, followed by uniaxial cycles. Failure load was and mechanism of failure for each graft was identified. RESULTS: Of the 6 pre-shaped bone grafts, 3 (50 %) experienced a failure at the sawbone/screw interface, 2 (33 %) experienced a bone graft fracture, and 1 (17 %) a tendon avulsion during cycling. Of the 6 surgeon-shaped bone grafts, 3 (50 %) experienced failure at the sawbone screw interface, and 3 (50 %) experienced a bone block fracture. No significant differences in biomechanical properties measured during load-to-failure testing or failure modes were detected between the two graft types. CONCLUSION: Pre-shaped grafts exhibited a trend towards higher load and displacement at failure, although this was not statistically significant. These findings, along with potential cost and time savings, warrant further study on their impact on surgical efficiency and outcomes.

Duke Scholars

Published In

J Orthop

DOI

ISSN

0972-978X

Publication Date

October 2025

Volume

68

Start / End Page

163 / 170

Location

India

Related Subject Headings

  • 3202 Clinical sciences
  • 1199 Other Medical and Health Sciences
  • 1103 Clinical Sciences
 

Citation

APA
Chicago
ICMJE
MLA
NLM
Edge, C., Ernst, B., Sharma, A., Savsani, K., Satalich, J., O’Neill, C., … Goodloe, J. B. (2025). Comparison of load-to-failure in pre-shaped versus surgeon-shaped Achilles tendon allograft bone blocks. J Orthop, 68, 163–170. https://doi.org/10.1016/j.jor.2025.05.055
Edge, Carl, Brady Ernst, Aadi Sharma, Kush Savsani, James Satalich, Conor O’Neill, John Owen, and J Brett Goodloe. “Comparison of load-to-failure in pre-shaped versus surgeon-shaped Achilles tendon allograft bone blocks.J Orthop 68 (October 2025): 163–70. https://doi.org/10.1016/j.jor.2025.05.055.
Edge C, Ernst B, Sharma A, Savsani K, Satalich J, O’Neill C, et al. Comparison of load-to-failure in pre-shaped versus surgeon-shaped Achilles tendon allograft bone blocks. J Orthop. 2025 Oct;68:163–70.
Edge, Carl, et al. “Comparison of load-to-failure in pre-shaped versus surgeon-shaped Achilles tendon allograft bone blocks.J Orthop, vol. 68, Oct. 2025, pp. 163–70. Pubmed, doi:10.1016/j.jor.2025.05.055.
Edge C, Ernst B, Sharma A, Savsani K, Satalich J, O’Neill C, Owen J, Goodloe JB. Comparison of load-to-failure in pre-shaped versus surgeon-shaped Achilles tendon allograft bone blocks. J Orthop. 2025 Oct;68:163–170.
Journal cover image

Published In

J Orthop

DOI

ISSN

0972-978X

Publication Date

October 2025

Volume

68

Start / End Page

163 / 170

Location

India

Related Subject Headings

  • 3202 Clinical sciences
  • 1199 Other Medical and Health Sciences
  • 1103 Clinical Sciences