Skip to main content

Smarce1 and Tensin 4 Are Putative Modulators of Corneoscleral Stiffness.

Publication ,  Journal Article
Boazak, EM; King, R; Wang, J; Chu, CM; Toporek, AM; Sherwood, JM; Overby, DR; Geisert, EE; Ethier, CR
Published in: Front Bioeng Biotechnol
2021

The biomechanical properties of the cornea and sclera are important in the onset and progression of multiple ocular pathologies and vary substantially between individuals, yet the source of this variation remains unknown. Here we identify genes putatively regulating corneoscleral biomechanical tissue properties by conducting high-fidelity ocular compliance measurements across the BXD recombinant inbred mouse set and performing quantitative trait analysis. We find seven cis-eQTLs and non-synonymous SNPs associating with ocular compliance, and show by RT-qPCR and immunolabeling that only two of the candidate genes, Smarce1 and Tns4, showed significant expression in corneal and scleral tissues. Both have mechanistic potential to influence the development and/or regulation of tissue material properties. This work motivates further study of Smarce1 and Tns4 for their role(s) in ocular pathology involving the corneoscleral envelope as well as the development of novel mouse models of ocular pathophysiology, such as myopia and glaucoma.

Duke Scholars

Published In

Front Bioeng Biotechnol

DOI

ISSN

2296-4185

Publication Date

2021

Volume

9

Start / End Page

596154

Location

Switzerland

Related Subject Headings

  • 4003 Biomedical engineering
  • 3206 Medical biotechnology
  • 3106 Industrial biotechnology
  • 1004 Medical Biotechnology
  • 0903 Biomedical Engineering
  • 0699 Other Biological Sciences
 

Citation

APA
Chicago
ICMJE
MLA
NLM
Boazak, E. M., King, R., Wang, J., Chu, C. M., Toporek, A. M., Sherwood, J. M., … Ethier, C. R. (2021). Smarce1 and Tensin 4 Are Putative Modulators of Corneoscleral Stiffness. Front Bioeng Biotechnol, 9, 596154. https://doi.org/10.3389/fbioe.2021.596154
Boazak, Elizabeth M., Rebecca King, Jiaxing Wang, Cassandra M. Chu, Aaron M. Toporek, Joseph M. Sherwood, Darryl R. Overby, Eldon E. Geisert, and C Ross Ethier. “Smarce1 and Tensin 4 Are Putative Modulators of Corneoscleral Stiffness.Front Bioeng Biotechnol 9 (2021): 596154. https://doi.org/10.3389/fbioe.2021.596154.
Boazak EM, King R, Wang J, Chu CM, Toporek AM, Sherwood JM, et al. Smarce1 and Tensin 4 Are Putative Modulators of Corneoscleral Stiffness. Front Bioeng Biotechnol. 2021;9:596154.
Boazak, Elizabeth M., et al. “Smarce1 and Tensin 4 Are Putative Modulators of Corneoscleral Stiffness.Front Bioeng Biotechnol, vol. 9, 2021, p. 596154. Pubmed, doi:10.3389/fbioe.2021.596154.
Boazak EM, King R, Wang J, Chu CM, Toporek AM, Sherwood JM, Overby DR, Geisert EE, Ethier CR. Smarce1 and Tensin 4 Are Putative Modulators of Corneoscleral Stiffness. Front Bioeng Biotechnol. 2021;9:596154.

Published In

Front Bioeng Biotechnol

DOI

ISSN

2296-4185

Publication Date

2021

Volume

9

Start / End Page

596154

Location

Switzerland

Related Subject Headings

  • 4003 Biomedical engineering
  • 3206 Medical biotechnology
  • 3106 Industrial biotechnology
  • 1004 Medical Biotechnology
  • 0903 Biomedical Engineering
  • 0699 Other Biological Sciences