Skip to main content
construction release_alert
Scholars@Duke will be down for maintenance for approximately one hour starting Tuesday, 11/11 @1pm ET
cancel

Integrating medical physics into an EMR-based radiology feedback system for quality improvement.

Publication ,  Journal Article
Russ, MK; Solomon, J; Bache, S; Lafata, NM; Macdonald, EB; Samei, E
Published in: Journal of applied clinical medical physics
September 2025

Medical physicists play a critical role in ensuring image quality and patient safety, but their routine evaluations are limited in scope and frequency compared to the breadth of clinical imaging practices. An electronic radiologist feedback system can augment medical physics oversight for quality improvement. This work presents a novel quality feedback system integrated into the Epic electronic medical record (EMR) at a university hospital system, designed to facilitate feedback from radiologists to medical physicists and technologist leaders.The feedback system was designed to enable radiologists to report quality issues directly through a streamlined survey during report dictation. The feedback encompasses technical details including image noise, artifact, and contrast issues, as well as acquisition-related concerns such as positioning errors or protocol deviations. Submissions are routed to modality-specific teams consisting of technologist leaders and medical physicists, who investigate and address reported issues. The roles of medical physicists in this feedback system were evaluated over a 31-month period.Physicists addressed 9.3% of 515 tickets that warranted follow-up, with greater involvement in resolving technical quality issues including artifacts and issues related to noise and image contrast. Examples of physicist-led interventions included correcting radiography image processing settings, optimizing computed tomography dose settings, and identifying trends in ultrasound quality issues that prompted protocol updates and staff training.This work demonstrates the value of radiology quality feedback systems and the opportunity to address issues not typically identified during routine medical physics quality assurance. By leveraging radiologist feedback, physicists can enhance clinical practice, promote continuous improvement, and ensure consistent, high-quality imaging and safety for patients.

Duke Scholars

Published In

Journal of applied clinical medical physics

DOI

EISSN

1526-9914

ISSN

1526-9914

Publication Date

September 2025

Volume

26

Issue

9

Start / End Page

e70227

Related Subject Headings

  • Tomography, X-Ray Computed
  • Radiology
  • Quality Improvement
  • Quality Assurance, Health Care
  • Nuclear Medicine & Medical Imaging
  • Image Processing, Computer-Assisted
  • Humans
  • Health Physics
  • Feedback
  • Electronic Health Records
 

Citation

APA
Chicago
ICMJE
MLA
NLM
Russ, M. K., Solomon, J., Bache, S., Lafata, N. M., Macdonald, E. B., & Samei, E. (2025). Integrating medical physics into an EMR-based radiology feedback system for quality improvement. Journal of Applied Clinical Medical Physics, 26(9), e70227. https://doi.org/10.1002/acm2.70227
Russ, Megan K., Justin Solomon, Steve Bache, Nicole M. Lafata, Erin B. Macdonald, and Ehsan Samei. “Integrating medical physics into an EMR-based radiology feedback system for quality improvement.Journal of Applied Clinical Medical Physics 26, no. 9 (September 2025): e70227. https://doi.org/10.1002/acm2.70227.
Russ MK, Solomon J, Bache S, Lafata NM, Macdonald EB, Samei E. Integrating medical physics into an EMR-based radiology feedback system for quality improvement. Journal of applied clinical medical physics. 2025 Sep;26(9):e70227.
Russ, Megan K., et al. “Integrating medical physics into an EMR-based radiology feedback system for quality improvement.Journal of Applied Clinical Medical Physics, vol. 26, no. 9, Sept. 2025, p. e70227. Epmc, doi:10.1002/acm2.70227.
Russ MK, Solomon J, Bache S, Lafata NM, Macdonald EB, Samei E. Integrating medical physics into an EMR-based radiology feedback system for quality improvement. Journal of applied clinical medical physics. 2025 Sep;26(9):e70227.

Published In

Journal of applied clinical medical physics

DOI

EISSN

1526-9914

ISSN

1526-9914

Publication Date

September 2025

Volume

26

Issue

9

Start / End Page

e70227

Related Subject Headings

  • Tomography, X-Ray Computed
  • Radiology
  • Quality Improvement
  • Quality Assurance, Health Care
  • Nuclear Medicine & Medical Imaging
  • Image Processing, Computer-Assisted
  • Humans
  • Health Physics
  • Feedback
  • Electronic Health Records