Skip to main content
Journal cover image

High precision selenium isotope analysis using a Nu Sapphire collision–reaction cell MC-ICP-MS

Journal articles  - Journal Article
Kipp, MA; Piccirillo, LF; Peters, D
Published in: Journal of Analytical Atomic Spectrometry
October 1, 2025

Selenium is a redox-sensitive trace element that is both an essential nutrient and toxin. Studying selenium cycling in nature is of great interest to the fields of environmental health, geomicrobiology, chemical oceanography and volcanology. The six stable isotopes of selenium are fractionated during redox reactions, leaving fingerprints of redox conditions and micronutrient dynamics in modern and ancient environments. However, the study of selenium isotope variability in nature is plagued by analytical difficulties, including its low natural abundance and the prevalence of argon-based interferences in plasma-based mass spectrometers. Here we present a new approach to selenium isotopic analysis using a collision–reaction cell multiple collector inductively coupled plasma mass spectrometer. By using a He–N2 gas mixture, we can achieve near-complete removal of argon dimers from the beam, allowing precise analysis of all selenium isotopes. This new method enables greater analytical precision per nanogram of selenium analyzed and is also less sensitive to concentration mismatch between samples and standards. Future work can leverage CRC-equipped mass spectrometers to study subtle isotopic effects in low-selenium reservoirs.

Duke Scholars

Altmetric Attention Stats
Dimensions Citation Stats

Published In

Journal of Analytical Atomic Spectrometry

DOI

EISSN

1364-5544

ISSN

0267-9477

Publication Date

October 1, 2025

Volume

40

Issue

10

Start / End Page

2792 / 2802

Related Subject Headings

  • Analytical Chemistry
  • 3406 Physical chemistry
  • 3401 Analytical chemistry
 

Citation

APA
Chicago
ICMJE
MLA
NLM
Kipp, M. A., Piccirillo, L. F., & Peters, D. (2025). High precision selenium isotope analysis using a Nu Sapphire collision–reaction cell MC-ICP-MS. Journal of Analytical Atomic Spectrometry, 40(10), 2792–2802. https://doi.org/10.1039/d5ja00247h
Kipp, M. A., L. F. Piccirillo, and D. Peters. “High precision selenium isotope analysis using a Nu Sapphire collision–reaction cell MC-ICP-MS.” Journal of Analytical Atomic Spectrometry 40, no. 10 (October 1, 2025): 2792–2802. https://doi.org/10.1039/d5ja00247h.
Kipp MA, Piccirillo LF, Peters D. High precision selenium isotope analysis using a Nu Sapphire collision–reaction cell MC-ICP-MS. Journal of Analytical Atomic Spectrometry. 2025 Oct 1;40(10):2792–802.
Kipp, M. A., et al. “High precision selenium isotope analysis using a Nu Sapphire collision–reaction cell MC-ICP-MS.” Journal of Analytical Atomic Spectrometry, vol. 40, no. 10, Oct. 2025, pp. 2792–802. Scopus, doi:10.1039/d5ja00247h.
Kipp MA, Piccirillo LF, Peters D. High precision selenium isotope analysis using a Nu Sapphire collision–reaction cell MC-ICP-MS. Journal of Analytical Atomic Spectrometry. 2025 Oct 1;40(10):2792–2802.
Journal cover image

Published In

Journal of Analytical Atomic Spectrometry

DOI

EISSN

1364-5544

ISSN

0267-9477

Publication Date

October 1, 2025

Volume

40

Issue

10

Start / End Page

2792 / 2802

Related Subject Headings

  • Analytical Chemistry
  • 3406 Physical chemistry
  • 3401 Analytical chemistry