The American college of radiology diagnostic fluoroscopy dose index registry pilot: Dosimetric performance and benchmarking challenges.

Publication ,  Journal Article
Mann, SD; Miller, DL; Fong, G; Goode, AR; Marshall, EL; Nishino, T; Boxx, P; Ren, L; Topbas, C; Schoenfeld, AH; Singh, V; Zhang, J
Published in: Journal of applied clinical medical physics
February 2026

The ACR Diagnostic Fluoroscopy Dose Index Registry (DIR-Fluoro) is expanding to include diagnostic fluoroscopy. Variations in dose reference points and overhead radiography events may introduce unique challenges for benchmarking.To survey the technological status and dosimetric performance of fluoroscopes participating in the DIR-Fluoro pilot project, focusing on longitudinal stability and variability of fluoroscopic dose reporting accuracy across multiple institutions and vendors.Sixty-six fluoroscopic systems from nine institutions (24 facilities) were surveyed for facility type, fluoroscope type, image receptor type, age, dose reporting capabilities, and other key features. Of these, 56 were evaluable. Semi-annual measurements assessed reference air kerma (Ka,r) and air kerma area product (PKA) accuracy. Linear mixed-effects models evaluated changes in dose accuracy over time, incorporating system-specific random effects; models were compared using likelihood ratio testing. Radiation Dose Structured Reports (RDSR) contents were investigated to understand the challenges in benchmarking diagnostic fluoroscopy dose indices.Nearly 80% of units were tube-under-table fluoroscopes. Average age was 9.6 ± 5.2 years. Sixty-four percent of the units produced RDSRs. Median deviations for Ka,r and PKA were 1%-4%. Accuracy of PKA and Ka,r remained stable, with no significant time-dependent drift for RDSR-capable systems (p > 0.05). Incorporating detector type significantly improved performance for PKA measurements (p < 0.05 for all datasets); Ka,r models were generally best fit by simpler models (p > 0.05 for 3 of 4 datasets). Major discrepancies in RDSRs were observed, including differences in Ka,r reference point definitions and in event-level data. Overhead radiography exposures were not well distinguished from fluoroscope exposures. These issues resulted in inconsistencies in reported Ka,r values.Fluoroscopic dose indices were accurate and stable over time. Differences in RDSR availability result in data biased to newer systems with flat panel detectors. Discrepancies in RDSR content and inconsistent reference point definitions necessitate use of PKA as the primary benchmark metric.

Duke Scholars

Published In

Journal of applied clinical medical physics

DOI

EISSN

1526-9914

ISSN

1526-9914

Publication Date

February 2026

Volume

27

Issue

2

Start / End Page

e70458

Related Subject Headings

  • United States
  • Societies, Medical
  • Registries
  • Radiometry
  • Radiology
  • Radiation Dosage
  • Pilot Projects
  • Nuclear Medicine & Medical Imaging
  • Humans
  • Fluoroscopy
 

Citation

APA
Chicago
ICMJE
MLA
NLM
Mann, S. D., Miller, D. L., Fong, G., Goode, A. R., Marshall, E. L., Nishino, T., … Zhang, J. (2026). The American college of radiology diagnostic fluoroscopy dose index registry pilot: Dosimetric performance and benchmarking challenges. Journal of Applied Clinical Medical Physics, 27(2), e70458. https://doi.org/10.1002/acm2.70458
Mann, Steve D., Donald L. Miller, Grant Fong, Allen R. Goode, Emily L. Marshall, Thomas Nishino, Pavlina Boxx, et al. “The American college of radiology diagnostic fluoroscopy dose index registry pilot: Dosimetric performance and benchmarking challenges.Journal of Applied Clinical Medical Physics 27, no. 2 (February 2026): e70458. https://doi.org/10.1002/acm2.70458.
Mann SD, Miller DL, Fong G, Goode AR, Marshall EL, Nishino T, et al. The American college of radiology diagnostic fluoroscopy dose index registry pilot: Dosimetric performance and benchmarking challenges. Journal of applied clinical medical physics. 2026 Feb;27(2):e70458.
Mann, Steve D., et al. “The American college of radiology diagnostic fluoroscopy dose index registry pilot: Dosimetric performance and benchmarking challenges.Journal of Applied Clinical Medical Physics, vol. 27, no. 2, Feb. 2026, p. e70458. Epmc, doi:10.1002/acm2.70458.
Mann SD, Miller DL, Fong G, Goode AR, Marshall EL, Nishino T, Boxx P, Ren L, Topbas C, Schoenfeld AH, Singh V, Zhang J. The American college of radiology diagnostic fluoroscopy dose index registry pilot: Dosimetric performance and benchmarking challenges. Journal of applied clinical medical physics. 2026 Feb;27(2):e70458.

Published In

Journal of applied clinical medical physics

DOI

EISSN

1526-9914

ISSN

1526-9914

Publication Date

February 2026

Volume

27

Issue

2

Start / End Page

e70458

Related Subject Headings

  • United States
  • Societies, Medical
  • Registries
  • Radiometry
  • Radiology
  • Radiation Dosage
  • Pilot Projects
  • Nuclear Medicine & Medical Imaging
  • Humans
  • Fluoroscopy